44
●
BD
DMC-40x0 Command Reference
BD
FUNCTION:
Brushless Degrees
DESCRIPTION:
This command sets the commutation phase of a sinusoidally commutated motor. When using hall
effect sensors, a more accurate value for this parameter can be set by using the command, BC.
This command should not be used except when the user is creating a specialized phase
initialization procedure.
ARGUMENTS:
BD n,n,n,n,n,n,n,n or
BDA=n where
n is an integer between 0 - 360
°
.
n = ? Returns the current brushless motor angle (between 0-360
°
)
USAGE: DEFAULTS:
While Moving
No
Default Value
0
In a Program
Yes
Default Format
0
Command Line
Yes
Controller Usage
ALL CONTROLLERS
OPERAND USAGE:
_BDn contains the commutation phase of the specified axis.
RELATED COMMANDS:
Brushless Axis
Brushless Phase Begins
Brushless Commutation
Brushless Inputs
Brushless Modulo
Brushless Offset
Brushless Setup
Zero