![Galil Motion Control DMC-40x0 Series Скачать руководство пользователя страница 193](http://html1.mh-extra.com/html/galil-motion-control/dmc-40x0-series/dmc-40x0-series_command-reference-manual_558773193.webp)
DMC-40x0 Command Reference
PA • 183
PA
FUNCTION:
Position Absolute
DESCRIPTION:
The PA command will set the final destination of each axis. The position is referenced to the
absolute zero.
ARGUMENTS:
PA n,n,n,n,n,n,n,n or
PAA=n where
n is a signed integers in the range -2147483648 to 2147483647 decimal. Units are in encoder
counts.
n = ? Returns the commanded position at which motion stopped.
USAGE: DEFAULTS:
While Moving
No
Default Value
-
In a Program
Yes
Default Format
Position Format
Command Line
Yes
Controller Usage
ALL CONTROLLERS
OPERAND USAGE:
_PAn contains the last commanded position at which motion stopped.
RELATED COMMANDS:
Position relative
Speed
Acceleration
Deceleration
Begin
Position Formatting
EXAMPLES:
PA 400,-600,500,200
A-axis will go to 400 counts B-axis will go to –600
counts C-axis will go to 500 counts D-axis will go to
200 counts
BG;AM
Execute Motion and Wait for Motion Complete
PA ?,?,?,?
Returns the current commanded position after motion has
completed
:400, -600, 500, 200
BG
Start the move
PA 700
A-axis will go to 700 on the next move while the
BG
B,C and D-axis will travel the previously set relative
distance if the preceding move was a PR move, or will
not move if the preceding move was a PA move.