DMC-40x0 Command Reference
RC • 201
RC
FUNCTION:
Record
DESCRIPTION:
The RC command begins recording for the Automatic Record Array Mode (RA). RC 0 stops
recording .
ARGUMENTS:
RC n,m
where
n is an integer 1 thru 8 and specifies 2
n
samples between records. RC 0 stops recording.
m is optional and specifies the number of records to be recorded. If m is not specified, the DM
number will be used. A negative number for m causes circular recording over array addresses
0 to m-1. The address for the array element for the next recording can be interrogated with
_RD.
n = ? Returns status of recording. ‘1’ if recording, ‘0’ if not recording.
USAGE: DEFAULTS:
While Moving
Yes
Default Value
-
In a Program
Yes
Default Format
-
Command Line
Yes
Controller Usage
ALL CONTROLLERS
OPERAND USAGE:
_RC contains status of recording. ‘1’ if recording, ‘0’ if not recording.
RELATED COMMANDS:
Dimension Array
Record Data
Record Array Mode
EXAMPLES:
#RECORD
;
'Record
DM
Torque[1000]
;
'Define Array
RA
Torque[]
;
'Specify Record Mode
RD
_TTA
;
'Specify Data Type
RC
2
;
'Begin recording and set 4 msec between records
JG
1000;
BG
;
'Begin motion
#A
;
JP
#A
,
_RC
=1
;
'Loop until done
MG
"DONE RECORDING"
;
'Print message
EN
;
'End program