2
Gal Pro
Instruction 1.0
Subject
Example
Explanation
Fert.Units
L/M3
Via the "+" and "-" keys select one of the options:
Liter, Minutes, Ltr/M3, Relate
Frt.Flt.React
Ignor
Via the "+" and "-" keys select one of the options:
Ignor - The controller ignores fertilizer faults.
Pause - Fertilizer fault stops the irrigation. If there are more
valves in the sequence that are programmed "ignor", the
system will operate them.
WtrFlow M3/H
12
Enter the nominal flow rate of the valve. Zero means no flow
control.
UndrFlw.Dev.
30%
The percentage deviation below which the controller issues
an alarm.
UndrFlw.React
Alarm
Select one of the following options:
Ignor - The controller ignores the under flow fault.
Alarm - The controller issues an alarm but the irrigation
continues.
Fault - The controller issues an alarm and stops irrigation.
OverFlw.Dev.
25%
The percentage deviation above which the controller issues
an alarm.
OverFlw.React
Alarm
Select one of the following options:
Ignor - The controller ignores the under flow fault.
Alarm - The controller issues an alarm but the irrigation
continues.
Fault - The controller issues an alarm and stops irrigation.
Flw.Flt.Dly
5 Mins
The period of time (or M3, according to the definition "flow
dev. unit" in the "system setup" menu) that the controller
waits from the moment a flow fault occurs until the controller
actually issues a fault status.
Vlv.On Fert Way
Yes
Enables to operate a non fertilizing valve with another
fertilizing valve. Define "yes" for the non fertilizing valve.
Stop Cond. Input
0
Assign the condition input number to stop the valve.
Pause Cond.Input
1
Assign the condition input number to pause the valve.
CoValve Number
0
If you want to operate another valve along with this valve,
enter its number here. The covalve does not accumulate the
water and fertilizer and cannot contain another covalve. Any
valve number can be programmed in a sequence and be a
covalve as well.
Move to valve number 2 and the other valves by the next key.