0
Gal Pro
Instruction 1.0
Permanent Multiplication for Valves in a specific Sequence
Enter the Sequence Setup menu. Move down to Permanent Water Multiplication and change the %
according to your requirements.
A message about water multiplication appears in the following menus:
Sequence Status - Only for the sequences in which the water multiplication.
Valve Status - Only for the valves for which the water multiplication is defined.
Valve Information - Only for valves which are defined in a sequence for which water multiplication
has been defined.
Sequence Information - Only in sequences in which water multiplication has been defined.
Water Multiplication for Today Only for Valves in a Specific Sequence
Enter Sequence Status in the required sequence. Move down to Water Multiplication Today and
change the % as required.
Water Multiplication Today Only for a Single Valve
Enter Valve Status menu in the required valve screen. Move down to Water Multiplication Today and
change the % as required.
Operation According to Condition Input
As mentioned in the "Controller Setup" chapter, the controller has 3 inputs to which condition contacts
can be connected. There are several types of condition inputs upon which the controller definition
depends. The following are instructions for the connection and definition of the most widely used
condition contacts. If you wish to connect other types of condition contacts please contact technical
support at Galcon.
Pressure Stat Connection
Pressure stat contacts are connected to the pressure line and are designed to sense pressure set
points and close a contact during high or low pressure. Connect the electrical connection to the
controller condition input (2 wires).
Input Condition Definition for the Whole Controller
Enter the System Setup menu, move down to Pause Condition Input and enter the number of
condition input to which the pressure stat is connected.
Define the delay and controller reaction for the condition contact. Move down to Cond.1 OnDly-Sc,
this parameter defines the delay duration between the contact and the pause start. The time range is
between 0-3600 seconds. This time delay is very important for stabilizing the system and preventing
operation fluctuations.
Pause Contact Definition for Each Sequence Separately
If you wish to define a special condition contact for each sequence, make sure that the definition in
the System Setup as previously described is not defined.
Defining the sequences participating in the pause process:
Enter Sequence Setup and move down to Pause Condition Input and enter the condition input
11. Advanced Operation
Содержание Gal Pro 4
Страница 1: ...GalPro AC DC Operating Manual...
Страница 2: ......