10
Gal Pro
Instruction 1.0
Two wire solenoids for Gal Pro DC (black and red wires only) are connected in the same way (the
white wire connector is left unconnected). In this way the solenoid is "normally open" i.e. when the
output is idle the solenoid sends water. When inverting the command is required, simply switch
between the red and black wires.
Connection of solenoids for Gal Pro AC
The red wire has to be connected to the output and the second wire has to be connected to the
COM.
*It is highly recommended to mark with an indelible pen all of the output functions.
Connect all of the detachable connectors.
Alarm Output Connection
The alarm output is designed to send out an alarm. The alarm output can be connected to devices
such as: a siren, flashing lights, a cellular dialer that sends text messages etc. The alarm device is
operated via an external power supply for Gal Pro DC Controller with a relay switch connected to
the controller.
Alarm Connection Diagram:
3. Controller Installation
12VDC
OUT PUT
COMMON
Содержание Gal Pro 4
Страница 1: ...GalPro AC DC Operating Manual...
Страница 2: ......