Outline of the Configuration Process
NOTES
Only authorized Galaxy Dealers can register System & Workstation features (master operator login is required).
Review the requirements section in this manual as well as the manufacturer’s equipment guides.
Configure the partitions and zones in the alarm panel before importing into System Galaxy
Physically connect the panel’s 4100 serial module to the System Galaxy server using direct RS-232 connection or
using TCP/IP LAN to Lantronix connection (must run at 1200 baud)
QUICK STEPS
The steps below outline how to configure SG to interface with the Alarm Panel. See Chapter 3 for full steps.
STEPS
1.
Register System Galaxy for Alarm Panel Support (dealer/installer)
2.
Configure the Alarm Options as needed (master operator)
3.
Start the Alarm Panel Service and configure it to run “automatically”
Get to programming screens under Configure > Hardware > Alarm Panel…
4.
Add the alarm panel to System Galaxy
5.
Add any areas (partitions) to System Galaxy
6.
Add the points (zones) by importing with the GET POINT TEXT button
7.
Refresh the Hardware Tree to show all devices
SYSTEM GALAXY ALARM PANEL PROGRAMMING SCREENS: