GALaxy eHydro Elevator Controller Section 6
– Main CPU Faults & Detailed Faults
6-44
Table 6-0: Main CPU Faults
Faults
Description
Possible Cause/Suggested Fix
Car 8 Comm Loss
The group car is not
communicating with
Car 8
• Faulty wiring from R/T+ and R/T
- from car to car.
• Faulty U6 driver chip on 1132 board.
• Noise on shield wire. Connect shield only on one end.
• Noise on the c
ommunication wires. Run wires in separate
conduit.
Car Call Light Fuse
Car Call Light Fuse
Blown
• Check for short on the Car Call Light circuit.
Car Call Power Fuse
Car Call Power Fuse
Blown
• Check for short on Car Call Power circuit.
Car Com Device
Reset
Serial Car board reset
unexpectedly. Usually
caused by loss of
power to the
individual board.
• Usually caused by loss of power to the individual board.
Check for loose connection on power to board.
• Faulty I/O
board.
Car Gate Safe Fault
Car Gate safe fault
• The car was either running or preparing to run and lost a
car gate or car lock input. Check the adjustment of the door.
Car Safe Fault
The Car Safe Fault
occurs from the
wanting to run but
does not have a
critical input
energized. Some of
the conditions for a
car safe fault will also
cause other faults to
be logged.
• The car does not have the gate or lock inputs and is
running or trying to run
• The stop switch is open
• An inspection string input fault. Only one input
should be
on in the inspection string (AUTO, CTI, ICI, ACC or MRI)
• Gate or Lock Bypass switch is on when not on car top
inspection
Car Safe Fault Preop
The car had a car safe
fault while pre-
opening the door.
• The car lost the DZ input while
leveling into the floor and
the door was open.
Car Safe Fault Start
The car had an
onward call, had the
door close limit but
the car gate or door
locks did not make
after a 3 second time-
out.
• The locks are not making properly when the door
closes.
• The door is not closing properly.
Содержание GALaxy eHydro
Страница 50: ...GALaxy eHydro Elevator Controller Section 4 Troubleshooting 4 4 Figure 4 1 Main CPU NTS and Safety PAL System ...
Страница 66: ...GALaxy eHydro Elevator Controller Section 5 LCD Interface 5 2 5 2 LCD Menus 5 2 1 Elevator Status Figure 5 1 ...
Страница 83: ...GALaxy eHydro Elevator Controller Section 5 LCD Interface 5 19 5 2 5 2 Remove Relocation I O Figure 5 16 ...
Страница 87: ...GALaxy eHydro Elevator Controller Section 5 LCD Interface 5 23 5 2 8 1 Group Comm Status Figure 5 20 ...
Страница 88: ...GALaxy eHydro Elevator Controller Section 5 LCD Interface 5 24 5 2 8 2 Group Can Comm Status Figure 5 21 ...
Страница 89: ...GALaxy eHydro Elevator Controller Section 5 LCD Interface 5 25 5 2 8 3 Car Can Comm Status Figure 5 22 ...
Страница 91: ...GALaxy eHydro Elevator Controller Section 5 LCD Interface 5 27 5 2 8 5 SPI Comm Status Figure 5 24 ...