GALaxy eHydro Elevator Controller Section 7
– Main CPU Adjustable Variables
7-14
Table 7-4: Service Options
Field Variable
Min
Max
Initial Units
Acc Door Cls
0
1
0
-
Access Door Close.
When on access operation the car
runs with the Door Lock and GS open. By turning this
parameter on, the car needs to have the gate switch
signal ON in order to run. It should be used on
hoistways where the car door will physically hit
something if moved on access operation
Access Bot Fl
Bottom
Floor
Top
Floor
1
floor
Access Bottom Floor.
Floor for bottom access
Access Top Fl
Bottom
Floor
Top
Floor
2
floor
Access Top Floor.
Floor for bottom access
Att Buz ctrl
0
1
1
-
Attendant Buzzer Control.
0 = Hall Calls only
1 = Hall Calls and Car Calls
Att CC frm HC
0
1
0
-
Attendant Car Call from Hall Call.
1 = When the car is on Attendant service the
respective car call will register when a hall call is
registered.
CCPBS Grp Sec
0
1
0
-
CCPBS On Group Car Call Security.
This variable
enables Car Call Push Button Security with group car
call lockout switches. The configuration file (CONS)
setting for security type and car call push button
security must also be set.
CCS on Sabb
0
1
0
-
Car Call Security on Sabbath.
When this parameter is
enabled, sabbath car calls will not latch on floors that
have been secured using car call lockouts security
CEOF Cntrl 2
0
15
0
-
Car Elevator Off Options 2:
+1= Keep doors Closed (do not cycle on reversal),
+2 = Do not blink Elevator Off Light,
+4 = Elevator Off Auto Reset With Timer,
+8 = Enable Elevator Off Light to indicate the car
finished recall of elevator off mode
Содержание GALaxy eHydro
Страница 50: ...GALaxy eHydro Elevator Controller Section 4 Troubleshooting 4 4 Figure 4 1 Main CPU NTS and Safety PAL System ...
Страница 66: ...GALaxy eHydro Elevator Controller Section 5 LCD Interface 5 2 5 2 LCD Menus 5 2 1 Elevator Status Figure 5 1 ...
Страница 83: ...GALaxy eHydro Elevator Controller Section 5 LCD Interface 5 19 5 2 5 2 Remove Relocation I O Figure 5 16 ...
Страница 87: ...GALaxy eHydro Elevator Controller Section 5 LCD Interface 5 23 5 2 8 1 Group Comm Status Figure 5 20 ...
Страница 88: ...GALaxy eHydro Elevator Controller Section 5 LCD Interface 5 24 5 2 8 2 Group Can Comm Status Figure 5 21 ...
Страница 89: ...GALaxy eHydro Elevator Controller Section 5 LCD Interface 5 25 5 2 8 3 Car Can Comm Status Figure 5 22 ...
Страница 91: ...GALaxy eHydro Elevator Controller Section 5 LCD Interface 5 27 5 2 8 5 SPI Comm Status Figure 5 24 ...