Compliance to standards 

EMC 

EN55022:1998 + A1:2000, A2:2003 – Information technology 
equipment. Radio disturbance characteristics. 

EN55024:1998 + A1:2000, A2, 2003 – Information technology 
equipment. Immunity characteristics. 

EN 50121-4: 2000 -  Railway applications, emission and 
immunity 

This equipment has been tested and found to comply with the 
limits for a Class B digital device, pursuant to part 15 of the 
FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference in a residential 
installation. This equipment generates, uses and can radiate 
radio frequency energy and, if not installed and used in 
accordance with the instructions, may cause harmful 
interference to radio communications. However, there is no 
guarantee that interference to radio or television reception, 
which can be determined by turning the equipment off and on, 
the user is encouraged to try to correct the interference by 
one or more of the following measures: 

 Re-orient 

or 

relocate the receiving antenna. 

 

Increase the separation between the equipment and 
receiver. 

 

Connect the equipment into an outlet on a circuit 
different from that to which the receiver is connected. 

 

Consult the dealer or an experienced radio/TV 
technician for help 

Safety 

EN60950-1:2001 + A11:2004 – Specification for information 
technology equipment, including electrical business 
equipment. 
BS6317:1992 (Clause 13.9) - Specification for simple 
telephones for connection to public switched telephone 
networks run by certain public telecommunication operators. 
EN50371:2002 - Generic standard to demonstrate the 
compliance of low power electronic and electrical apparatus 
with the basic restrictions related to human exposure to 
electromagnetic fields (10 MHz - 300 GHz). General public. 

Содержание Titan

Страница 1: ...20 0115 001 Iss 2 Jul 2008 CN33078 001 Installation and User Guide Rugged VoIP Telephone Titan Commander VR and Help Point models GAI TRONICS A division of Hubbell Ltd Titan Commander Vandal Resistant...

Страница 2: ...VR and Help Point 15 6 Connections and Installation 17 6 1 General 17 6 2 IMPORTANT SAFETY INFORMATION 18 6 3 Emergency Services warning 18 6 4 Titan Installation 19 6 5 Titan Connections 19 6 6 Comma...

Страница 3: ...es are securely clamped in the clamps provided Failure to do so could result in an unsafe installation Take adequate precautions when opening the case or installing If in doubt isolate connections els...

Страница 4: ...VoIP Telephone 4 Titan aluminium bodied handset telephone Commander rugged glass reinforced polyester handset telephone...

Страница 5: ...andal Resistant VR handsfree telephone FRONTPLATE MICROPHONE SPEAKER LED FLUSH 25mm CALL BUTTON Help Point handsfree telephone FRONTPLATE MICROPHONE SPEAKER LED REAR ENCLOSURE PALM OPERABLE STAINLESS...

Страница 6: ...password Recommended to prevent unauthorised changes to the phone s configuration Make sure to record these details securely Refer to configuration guide available from website 3 Check for power and...

Страница 7: ...oIP telephones Web pages Configuration file Command Line interface CLI Web pages held within the telephone can be accessed over the network using a browser such as Internet Explorer to view and change...

Страница 8: ...Select the appropriate sized gland Use the smaller gland for cables diameters 4 7mm 0 16 0 27in Use the larger gland for cable diameters 8 13mm 0 3 0 5in 3 From the outside of the case insert the sel...

Страница 9: ...rear enclosure is left unused 2 Any additional holes are drilled into the telephone enclosure 3 Plastic bushes are not used on all fixing holes 2 Mark the wall with hole centres based on the dimension...

Страница 10: ...of 100mm to 200mm diameter 4 8in or on to square or rectangular section uprights of 100mm to 150mm 4 6in across the mounting surface NOTE Banding straps large scale worm drive clamps are not included...

Страница 11: ...ones supplied for flush mounting have a slightly different faceplate to those supplied with a rear enclosure in particular the fixing holes are in different positions and there are no corner cut outs...

Страница 12: ...mooth surface Do not rely on this gasket to keep water out if mounting directly to rough surfaces such as brickwork in these cases use additional sealant around the edges to ensure a weatherproof seal...

Страница 13: ...y making the appropriate connections section 6 5 5 Reconnect the ringer Secure the telephone Front Casing to the Rear Casing 5 3 2 Pole mounting Kit No 100 02 0208 001 This accessory is for mounting G...

Страница 14: ...the band may also be sawn off 5 3 3 Desk mounting Rake For horizontal surfaces greater than 150 x 280mm 6 x 11in use the free standing desk mounted method below To provide a rake for convenient opera...

Страница 15: ...dentical 5 4 1 Wall Pole Mounting When wall or pole mounted VR and Help Point units must be fitted inside a dedicated rear enclosure The rear enclosure is identical to the Titan enclosure although usu...

Страница 16: ...s Select appropriate screws wall plugs etc for the type of wall bearing in mind that the weight of the complete phone is around 1 5kg 3 3lbs 9 Route the cable to within the recess and make connections...

Страница 17: ...ng the telephone in inclement weather conditions or by negligence Failure to do so may result in an unsafe condition and will invalidate your warranty Insert each cable through its gland body and tigh...

Страница 18: ...ated and and have an overall insulated outer sheath covering both conductors They must be appropriately rated and certified Examples of suitable ratings for PVC cords are IEC 60227 designation H05 VV...

Страница 19: ...mains wiring to this product that is not wholly run within trunking it is important that the strain relief is correctly installed and tested to ensure there will be no disturbance to the wire termina...

Страница 20: ...oint units if powering from 24Vdc NOTE Earlier models produced prior to May 2008 are 48Vdc only Check the connector legend as shown above If it is marked AUX it can accept voltages between 24 and 48V...

Страница 21: ...sition and orientation 2 The Commander telephone can be installed vertically to a wall or pole or used horizontally on a desk Select the required mounting method section 5 and mount the rear casing fi...

Страница 22: ...2 5A at 250Vac 1A at 24Vdc Refer to safety information in section 6 2 OP1 OP2 Clamp Clamp Network cable Connection to Output 1 Barrier Cabling example showing connection to Output 1 E OP1 OP2 E NC R L...

Страница 23: ...m the rear enclosure if supplied by undoing the four retaining screws A 3mm Allen key is required 2 VR and Help Point telephones are intended for vertical installation to a wall or pole or flush mount...

Страница 24: ...our warranty obligations GAI Tronics are able to offer various levels of maintenance packages installation and commissioning packages and technical support from ad hoc repairs to full maintenance con...

Страница 25: ...oving parts Ringer loudness 80dBA 1m Handset Titan Commander Suitable for inductive coupling to Hearing Aids having a T switch position Tested to ETS 300 381 Network 10 100 BaseT Ethernet RJ45 Cat5 or...

Страница 26: ...max 20 entries Numbers or URIs with comfort tones Divert to next in list if the call fails Environmental limits Temperature Operating 20 C to 60 C 4 F to 140 F Storing 40 C to 70 C 40 F to 158 F Relat...

Страница 27: ...nce to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Re o...

Страница 28: ...that the product is classed as Electrical or Electronic Equipment and should not be disposed with other household or commercial waste at the end of its working life The Waste of Electrical and Electro...

Страница 29: ...29 VoIP Telephone 9 CE Declaration...

Страница 30: ...ensing and copyright as follows Module License u boot GPL V2 Linux kernel GPL V2 Busybox GPL V2 Opal PWLib Mozilla Public License V1 1 Modutils GPL V2 MTD GPL V2 NTP David L Mills Copyright Notice The...

Страница 31: ...31 VoIP Telephone...

Страница 32: ...Brunel Drive Stretton Park Burton on Trent DE13 0BZ England Tel 01283 500500 Fax 01283 500400 www gai tronics co uk The policy of GAI Tronics is one of continuous improvement therefore the Company res...