19
VoIP Telephone.
6.4. Titan
Installation
1. To prepare for installation, open the door (where fitted), then undo the
four retaining screws to remove the faceplate from the rear enclosure. A
3mm Allen key is required.
Caution – take care to support the spring-loaded door whilst open
to prevent it slamming shut and trapping fingers.
2. The Titan telephone is intended for vertical installation to a wall or pole.
Select the required mounting method (section 5) and mount the rear
enclosure first where applicable.
3. Route the required cables through glands as appropriate, and make
connections following section 6.5. When fitting mains wiring to this
product that is not wholly run within trunking, it is important that the
strain relief is correctly installed and tested to ensure there will be no
disturbance to the wire terminations. As a minimum the cable must
withstand a pull of 100N (approx 10kg force or 22.5lbf) without visible
movement. If conduit is used, mains cables must be secured elsewhere.
4. Re-fit the faceplate ensuring a weatherproof seal
5. Test the operation of the telephone. Installation is now complete.
6.5. Titan
Connections
Make the appropriate connections as shown on the diagrams below.
0V
+
0V
OP2
OP1
-
IP1 IP2 IP3 IP4
48Vdc
1A
-T
RJ45 Network connector
(under back-box)
Power connections
Input connections
Serial port
Output connections
Clamping position
for power and input
cables
Clamping position
for output cables
Back-box
Содержание Titan
Страница 29: ...29 VoIP Telephone 9 CE Declaration...