background image

12

@futechtools

Facebook

futech-tools

LinkedIn

futech-tools

YouTube

JOIN US

futech-tools.com

World Wide Web

or environmental contamination. 

By disposing of the product irrespon-

sibly you may enable unauthorized 

persons to use it in contravention of 

the regulations, exposing themselves 

and third parties to the risk of severe 

injury and rendering the environment 

liable to contamination.

 ∙ The product must not be disposed 

with household waste. Dispose of the 

product appropriately in accordance 

with the national regulations in force in 

your country.

 

Remove batteries from a device if it is 

not used for several months to prevent 

damage.

If your instrument does not reach the re-

quired  tolerance,  it  should  be  returned 

to your service centre or to your reseller 

for service. Repairs carried out by unau-

thorised personnel will automatically in-

validate the guarantee. 

TECHNICAL INFORMATION

accuracy

± 2°c

temperature range

± -20°c ~ 300°

display

2,4 inch high resolutions color screen

sensitivity

0,15°c

emissivity

0,10 ~ 1,00 (adjustable)

optical resolution

10:6

laser class

not applicable

response time

0,15 sec.

special response time

6 ~14 µm

screw thread

1/4"

indication range

the thermal image can be mixed on the 

screen with an optical image

protection

ip54

dimensions (l x b x h)

212 x 95 x 62 mm

weight

320 g

operating temperature

-5°c ~ 40°c

storage temperature

-20°c ~ 50°c

power supply

4x aa alkaline

relative humidity

10% ~ 80%rh

Содержание TEMPVIEWER3600

Страница 1: ...TEMPVIEWER3600 MANUAL...

Страница 2: ...that the bag and instrument are dry otherwise condensation may occur in the device Make sure that the windows are free of dirt and clean them using a soft cloth and a glass cleaning product only Alway...

Страница 3: ...tton 3 Battery compartment 4 Selection Enterbutton 5 Micro SD card 6 Navigation 7 Infrared sensor 8 Camera 9 LED light 10 Record button 11 Thread 1 4 Menu a Temperature unit C F b Background temperatu...

Страница 4: ...average emission power to a black radiator at the same temperature Emission is for most materials between 0 10 and 1 00 Materials with low emissivity 0 60 emit little energy typi cally for materials...

Страница 5: ...t ratio of 10 6 This means that at a measu rement at a distance of 100cm of the object the measuring surface is approximately 60x60cm in size GOOD TO KNOW An infrared thermometer must adapt to ambient...

Страница 6: ...roSD card aim the Tempviewer3600 on the surface to measure and press the Recording key Store photos yes no will appear on the screen Press the Power Menu key to save the image press the Select Enter k...

Страница 7: ...u a Unit C F The Tempviewer3600 can measure in both C and F To switch between these units press the Power Menu key Move with the Navigation buttons and to the Tem perature Unit C F option a and confir...

Страница 8: ...1 00 Look for the correct value in the table In case of doubt set the emissivity value to 0 95 To set the emissivity press the Power Menu key Move with the Navigation buttons and To the Emissivity Val...

Страница 9: ...to 25 000 images can be saved The menu shows the number of saved pictures To view saved images press the Power Menu key and move with the Navigation keys and To Saved pictures i and confirm with Selec...

Страница 10: ...w to counteract them The product is not to be operated until the user has been instructed on how to work with it LIMITS OF USE Environment Suitable for use in an atmosphere appro priate for permanent...

Страница 11: ...cted to mechanical shock for example blows or falling the product may be damaged or peo ple may sustain injury When setting up the product make sure that the accessories are correctly adapted fitted s...

Страница 12: ...al months to prevent damage If your instrument does not reach the re quired tolerance it should be returned to your service centre or to your reseller for service Repairs carried out by unau thorised...

Отзывы: