To work 

 ∙ Insert 4x AA batteries into the device. Consider the polarity. This is indicated in the 

device.

 ∙ Press 5 sec. On the “Power / Menu key” to turn on the unit.

 ∙ During the measurements there is a central mark to see. The measured tempera-

ture of this point is displayed in the upper left corner of the screen. The emissivity 

value is shown in the upper right corner. At the bottom left, the minimum and maxi-

mum values   are displayed within the measurement range. If desired, this minimum 

and maximum value can be displayed with a marker on the displayed thermal / 

visual image. (See min. / Max. Value)

 ∙ To save images on the MicroSD card, aim the Tempviewer3600 on the surface to 

measure and press the “Recording key.” “Store photos yes no” will appear on the 

screen. Press the “Power / Menu key” to save the image, press the “Select / Enter 

key” if you don’t want to save the image. If “FULL” appears at the bottom of the 

screen, you must clear the MicroSD card.

 ∙ To switch off the device, press the “Power / Menu key” for 5 seconds until the unit 

starts counting down.

Removing noise

Does the image display noise? Then start the device and make sure the sensor is clo-

se to the work surface. Press 5 seconds on the Navigation key 

~

 until “Adjust” appears 

on the screen. This process takes about 30sec.

Led light

Tempviewer3600 features an LED light. This can be activated by pressing the Record 

key (10) for about 5 seconds. Repeat this step to turn off the LED light again.

Содержание TEMPVIEWER3600

Страница 1: ...TEMPVIEWER3600 MANUAL...

Страница 2: ...that the bag and instrument are dry otherwise condensation may occur in the device Make sure that the windows are free of dirt and clean them using a soft cloth and a glass cleaning product only Alway...

Страница 3: ...tton 3 Battery compartment 4 Selection Enterbutton 5 Micro SD card 6 Navigation 7 Infrared sensor 8 Camera 9 LED light 10 Record button 11 Thread 1 4 Menu a Temperature unit C F b Background temperatu...

Страница 4: ...average emission power to a black radiator at the same temperature Emission is for most materials between 0 10 and 1 00 Materials with low emissivity 0 60 emit little energy typi cally for materials...

Страница 5: ...t ratio of 10 6 This means that at a measu rement at a distance of 100cm of the object the measuring surface is approximately 60x60cm in size GOOD TO KNOW An infrared thermometer must adapt to ambient...

Страница 6: ...roSD card aim the Tempviewer3600 on the surface to measure and press the Recording key Store photos yes no will appear on the screen Press the Power Menu key to save the image press the Select Enter k...

Страница 7: ...u a Unit C F The Tempviewer3600 can measure in both C and F To switch between these units press the Power Menu key Move with the Navigation buttons and to the Tem perature Unit C F option a and confir...

Страница 8: ...1 00 Look for the correct value in the table In case of doubt set the emissivity value to 0 95 To set the emissivity press the Power Menu key Move with the Navigation buttons and To the Emissivity Val...

Страница 9: ...to 25 000 images can be saved The menu shows the number of saved pictures To view saved images press the Power Menu key and move with the Navigation keys and To Saved pictures i and confirm with Selec...

Страница 10: ...w to counteract them The product is not to be operated until the user has been instructed on how to work with it LIMITS OF USE Environment Suitable for use in an atmosphere appro priate for permanent...

Страница 11: ...cted to mechanical shock for example blows or falling the product may be damaged or peo ple may sustain injury When setting up the product make sure that the accessories are correctly adapted fitted s...

Страница 12: ...al months to prevent damage If your instrument does not reach the re quired tolerance it should be returned to your service centre or to your reseller for service Repairs carried out by unau thorised...

Отзывы: