110
19.3 mm
4-M3
7.0 mm
21.6
mm
WARNING
If using screws to mount the CGY to the helicopter, it is imperative
to ensure that the machine does not vibrate excessively.
*Please do not mount with machine screws with vibration, please mounting with a dedi-
cated mounting pad.
M
OUNTING
O
F
CGY W
ITH
S
CREWS
Drill holes in the plate
Refer to the figure below. Drill
holes in the mounting plate
accordingly.
Screw size for attachment
The effective length of the screw hole of
the CGY main unit is 7 mm.
Use the M3 screw whose length is less
than the plate thickness plus 7 mm.
Mounting
Attach the CGY to the mounting plate
using M3 screws from the bottom of the
plate as shown in the example.
Ensure that the screws are no longer than
the plate thickness plus 7 mm.
Notes:
*Ensure that these mounting screws will
not come loose during flight.
*As the CGY case is aluminum, please be
careful not to over-tighten the mounting
screws.
CGY755 has no antenna
Содержание CGY755
Страница 112: ......