49
SWH. BASIC screen 3/5
Cond
From 2/5
Go to 4/5 from any
cursor position
*The current condition number of CGY is displayed.
*The setting with "C#" display can be set for each condition.
1. Use the [ /+] or [ /-] key to move the cursor to "C#" and
press the [Enter] key to enter the condition selection
mode. Use the [ /+] or [ /-] key to select the condition
number "C#" and press the [Enter] key to decide the
condition number.
2. Next, adjust value of the condition selected by the [ /+]
or [ /-] key, and press the [Enter] key to enter the setting
mode. Use the [ /+] and [ /-] keys to change the setting
value. When you are done, press the [Enter] key to exit
the setting mode.
:
:
:
(7) SWS. Dir: Swash direction setting
This selects the aileron, elevator and collective pitch
direction. Reverse the direction when the stick move-
ment and swash movement are opposite. Each time
you press the [ /+] or [ /-] key, the polarity switches.
(8) SWS. Rate: Rate adjustment
The Swash Rate settings are used to set a known base cyclic throw for
the gyro to calculate the compensations and gain scale. This value does
not represent the total cyclic throw, but rather shows the gyro a known
point for the gyro to understand the helicopters geometry. It is important
to note that one setting applies to both roll and pitch axes; they are not
individually adjusted. Use the [ /+] or [ /-] key to make an adjustment.
(DUAL RATES MUST BE 100)
-Suggested amount of base cyclic pitch
*800 size – 10 degrees
*700 size – 9 degrees
*600 - 550 size – 8 degrees
*500 size – 7 degrees
*450 and below- 6 degrees
Setting ranges: 0 ~ 100% Initial value: 50%