15
then full right, back to full left and then allow the stick to center within
one second; the same method applies for aileron and elevator servos.
WARNING
Never turn off the CGY760R/CGY755 while the GX (gyro) LED is
blinking green at high speed (about 5/sec).
*If the power is turned off while high-speed blinking, a data error will occur and all data
will be initialized. It is very dangerous to fly as it is.
Governor operating precautions:
Governor
When the throttle servo is connected to the CGY760R/CGY755, the
battery fail-safe function within the CGY760R/CGY755 must be setup
and enabled.
Throttle fail safe function (transmitter setting): Use the fail safe func-
tion for the channel that turns the governor on and off to set the fail
safe position to the point at which the governor is turned off. With this
setting, when the system enters the fail safe state, the governor will be
turned off, and the receiver throttle signal (fail safe position preset) will
be output directly.
When using the condition hold function on the transmitter, always
set the throttle servo maximum operating point to less than the point
at which the governor is activated. If this is not done the governor
may activate while in condition hold.
While preparing for flight or starting the engine, always ensure the
throttle remains below the governor activation point and do not select
any flight modes that may activate the governor.
If you prefer to activate the governor while the model is still on the
ground, always ensure that you have at least -1 degrees of pitch in the
model before activating the governor. This negative pitch is neces-
sary to prevent an unexpected lift off as the governor activates and the
head speed increases to the desired RPM.