6.5
C70 Configure FI-30
To return to normal PAGE, press
SET
when the text [rET] is
displayed.
In the configuration you will be able to tell the Nexus Network
where you have installed the log and Wind transducer.
This is important because you may optionally install those
transducers at the Server too.
6.5.1
C71 Wind-master
[On]
= the Wind transducer is connected at the Wind Data
instrument.
[OFF] =
the Wind transducer is connected at the FI-30 Server.
6.5.2
C72 Log-master
[On]
= the log transducer is connected at the Wind Data
instrument.
[OFF] =
the log transducer is connected at the FI-30 Server.
6.5.3
C73 Function on terminal In3
Select function on the terminal pin 3. The following functions
are available:
[TMP]
Standard temperature function from the log
transducer.
[TRM]
Use the external trim button for the STEER Pilot function.
[SPT]
Use the external trim button for the SPEED TRIM function.
[MOB]
Use the external trim button for the M.O.B. function.
[Roll]
Use the roll sensor to compensate Wind speed and angle.
(Not yet available, at the time for this manual).
When the selection roll is made, further settings in calibration can be made to correct
the offset angle. See C68 6.4.8. You may still use the water temperature by connecting
the log transducer at the Server.
When Speed Trim [SPT] is selected, a press on the external trim button will transmit
the trim command on the Network to all instrument. To be able to set both the STEER
reference and the TRIM reference, the optimum way is to connect one trim button for
speed to the Wind instrument and connect one trim button for Compass and Wind
angle to the Server. Such a installation gives you the opportunity to trim speed and
angle at two separate buttons.