19
5.5.5
Battery voltage [BAT], option
The text [BAT] will display battery voltage. The voltage is
measured inside the instrument and will not compensate for any
voltage drop caused by installation.
5.5.6
Boat speed [BSP], option
The text [BSP] will display boat speed (water speed). The text [BSP] will toggle with
selected unit, i.e. (KTS), (KMH) or (MPH).
As an option, you may add or remove displaying boat speed [BSP], trip log [TRP]
and water temperature [TMP]. See further under calibration.
5.5.7
Trip log [TRP], option
The text [TRP] is displayed and will show trip distance from 0.00 to 99.9 nautical miles,
kilometre or miles. After 99.9, 0.00 is displayed. Clear trip by pressing
CLEAR
.
5.5.8
Water temperature [TMP], option
The text [TMP] is displayed with water temperature in Celsius or Fahrenheit.
This function require a FI-30 log transducer.
5.5.9
Trim function for optimum Wind angle or speed, option
The text [TRM] and [OFF] is displayed when this function is off.
The trim function can be used as an aid to keep the correct
tacking angle or to discover speed changes caused by sail or rig
trimming. Some of the functions can only be used when the
Wind Data is connected to Nexus Network.
As the first example we will use [TRM AWA] (
TR
i
M
A
pparent
Wind
A
ngle).
To trim on wind angle deviation, select the text:
Press
CLEAR
, the display will flash. Select [AWA] with
MINUS
and confirm with
SET.
Select the level of dampening [d0-d9] and confirm with the
SET.
The default (or latest used) Wind angle is displayed. You may
accept the proposed angle by pressing the
SET
or enter a new
Wind angle with
PLUS
,
MINUS
and
PAGE
before confirming
with
SET.
The entered Wind angle will be lost when power off. You may
however select a default Wind angle in set-up. See C64 6.4.7.
Every time you select this function, or after power up, the pre-set value is proposed.