You can now connect the first FT636 IP Interface for configuration (power and network).
A web-browser is opened on the PC (Internet Explorer, Firefox, Opera, ...) and the following is en-
tered in the address bar:
http://192.168.16.191
The configuration page of the FT636 IP Interface appears (see below).
Select „Configuration 0 (TCP/IP)“ in the entry field Mode, click „Apply“ and then switch to the page
„Application“.
Change the „local IP address“ to 192.168.16.192.
Change the „target IP address“ to 192.168.16.191, then click „Apply“ .
IMPORTANT:
As the address has changed, the browser address line has to be changed to
http:
//192.168.16.192
in order to complete the configuration.
Now return to the page „System“ and select „standard operation“ in the entry field „Mode“. Now
click „Apply“ again. The system will start.
Now you can also connect and start the second system (power and network).
This still can be reached via
http://192.168.16.191
and is now set to the mode „standard operati-
on“ on the page „System“. It will start after clicking „Apply“.
You can determine that both IP Interfaces have connected if a terminal (Windows PC with hype-
terminal, see below for settings) is connected to the serial interface when starting. Different status
messages will appear. If there is a Syslog-Server (for example KIWI Syslog Server, Windows,
Freeware) in the network, it will receive the same messages. These can be read along in the logfi-
le.
The devices are now configurated as follows:
1. FT636 IP Interface
2. FT636 IP Interface
local IP address:
192.168.16.191
192.168.16.192
target IP address:
192.168.16.192
192.168.16.191
net mask:
255.255.255.0
255.255.255.0
ports:
audio/AF
10000
10000
serial/control data 10001
10001
web server
80
80
The devices are now ready to use in a local network (without routing, one segment). They will
make contact at once and a connection is established.
If you want to change the ports, please note the following limitations:
Web Server Port 80 is standard. If you change this port, the port number has to be indicated in the
address bar of the browser. If there is an adjustment, to 10025 for example, you have to enter
http://192.168.16.191:10025 in the browser.
Do not use a port lower than 1024. That is where the predefined ports of the TCP standard are
(well known ports), which are used by other programs/services.
The highest possible port number is 65535.
The settings of the serial interface are:
- 9600 bit/s
- 8 data bits
- no parity
- 1 stop bit
- no handshake
ATTENTION:
use a crossover cable