IP Interface
In the local network, in the same network segment
Major 5a control head
IP Interface
Ethernet
switch
Configuration examples
This is the easiest configuration and basically corresponds to the above explained introductory
example.
The following specifications are valid for this example:
- The FT636 IP Interfaces are connected to the existing network.
- The network part of the IP address is 172.16 (in this case the first two digits).
- The network mask is 255.255.0.0 (determines the network part of the address).
- The FT 636 IP Interfaces are assigned the following IP addresses:
1) 172.16.200.101
2) 172.16.100.201
The steps to configuration:
1. Assign a second IP address to the configuration PC (for example 192,168,16.254,see above).
IMPORTANT:
In any case the first three digits have to be 192.168.16.
2. Connect the IP Interfaces to the network (currentless).
3. Turn on the first IP Interface (supply power).
4. Start a browser on the PC.
5. Enter „http://192.168.16.191“ into the address bar of the browser.
6. Choose „Configuration 0“ in the field „Mode“ on the now appearing web page, click „Apply“
and switch to the page „Application“.
The page for the network configuration will appear.
7. The following fields have to be changed:
local IP address:
172.16.200.101
target IP address
172.16.100.201
network mask
255.255.0.0
Click on „Apply“.
8. In order to check the settings in the browser enter 172.16.200.101 in the address bar,
because the IP Interface can now only be contacted under the new address.
9. Proceed with the second IP Interface according to steps 2. - 8.
IMPORTANT
: The differences in the IP addresses have to be observed.
local IP address:
172.16.100.201
target IP address
172.16.200.101
network mask
255.255.0.0
Click on „Apply“.
For this process it does not matter if the FT636 IP Interfaces are configurated at your workstation
or if they have already been installed at their operating site. The configuration interface can be re-
ached via the network at any time. Configuration at the workstation is only favorable for the turning
on of the devices (at first configurate the first device, then turn on the second).
IMPORTANT:
Be sure to attach stickers with the assigned IP addresses on the device.