Questions? Call (315) 298-5121, or visit us online at www.fulton.com
SECTION 2
RLN-IOM-2012-1205
INSTALLATION
2-23
6. Promptly apply solvent cement to end of pipe and
inside socket surface of fi tting. Cement should be
applied lightly—but uniformly—to inside of socket.
Take care to keep excess cement out of socket. Apply
second coat to pipe end
NOTE:
´
Time is critical at this stage. Do not allow primer to
dry before applying the cement.
7. Immediately after applying last coat of cement to pipe,
while inside socket surface and end of pipe are wet with
cement, insert end of pipe into socket, turn pipe 1/4
turn to distribute cement evenly, continue to insert pipe
until it bottoms out.
DIAMETER "C"
STAINLESS
3 1/2 IN. OR
4.35 CM
AIR GAP
ALL AROUND
THRU PIPE
VARIABLE
(3 1/4 IN. MIN.) - (20 IN. MAX.)
(8.255 CM MIN. - 50.8 CM MAX.)
DIAMETER "B"
ADJUSTABLE
WALL THUMBLE
WIDTH TO VARY WITH
WALL THICKNESS
DIAMETER "A"
COLLAR
END VIEW
SCREW OR BOLT EACH THUMBLE COLLAR
TO WALL (TYPICAL 4 PLACES) ORIENT
COLLAR AND CLAMPS AS REQUIRED
PIPE RETAINING
CLAMP, TYPICAL
EACH SIDE
FIGURE 11 - WALL THIMBLE INSTALLATION