background image

Battery on the Calcium Battery Type setting as this may damage your battery and / or reduce your battery 
life.   

Note: 

If the Fault Indicator LED illuminates Red, please check your connections as it’s likely that the Positive and 

Negative Leads are reversed. 

 

THE CHARGING PROCESS: 

 

1) Qualification - Battery Condition Check 

 

When the charger is first switched on it checks the battery condition to determine whether the battery needs 
reconditioning. During this qualification process it checks the internal impedance and initial voltage of the 
battery and it will determine how much charge current.

 

2) Enhanced Battery Rejuvenation - Blue Bulk LED Flashing Fast 

 

If the initial qualification detected that the battery was in poor condition, the patented rejuvenation process 
will begin automatically. During the rejuvenation process a high voltage equalizing and peak pulse 
reconditioning charge is used to repair the sulphated battery. This unique patented feature will break down 
and dissolve the lead-sulphate crystal build up on the battery plates which will extend the life of your battery. 
It can also balance out high concentrations of acid. 

3) Soft Start Charging - Blue Bulk LED Flashing Slow 

 

Gently charges the battery using a reduced charge output until the battery voltages reaches 11V. If the battery 
voltage doesn’t reach 11V within 6 hours, the safety timer protection will stop the unit from charging and the 
Red Fault LED and Blue Bulk LED will start flashing. 

 

4) Bulk Charging - Blue Bulk LED ON (Charge Voltage depends on battery type selection) 

 

Charge with the maximum selected charge output until the battery voltage reaches 14.1/14.4/14.7V. If the 
battery voltage doesn’t reach this within 24 hours, the safety timer protection will stop the unit from charging 
and the Red Fault LED will start flashing and the Blue Bulk LED will be ON. 

 

5) Absorption Charging - Green Absorption LED ON 

 

Uses a constant voltage while reducing the charging output current to ensure the battery receives a full charge 
without overcharging the battery. 

 

6) Equalization Charging - Blue Bulk LED and Green Absorption LED both flashing   

A well proven process that carefully overcharges the battery to restore it’s full capacity. The Equalization stage 
for CALCIUM Battery type selection is automatic. The Equalization stage for AGM&WET and GEL Battery Types 
only occurs if the initial start voltage is below 11 Volts. 

7) Battery Analysis - Green Full LED ON 

 

The battery analysis stage checks the condition of the battery after the charge cycle is completed. If the 
battery voltage drops too quickly during the analysis mode, this means the battery is probably faulty. If the 
battery analysis failed, this is indicated by the Green Full LED flashing.   

8) Float Mode - Full Green LED ON 

 

This stage allows you to keep the charger connected 24/7 to ensure your battery is well maintained and kept 
100% fully charged. Float mode will maintain the battery at a constant 13.6V. 

9) Long Term Maintenance - Full Green LED ON 

 

During long term maintenance / float mode, the unit will apply a special pulse charge to ensure the battery is 
kept in optimal condition.   

STEP 4 - Disconnecting the Battery charger from Battery 

 

 

If the Battery is out of the vehicle: 

 

(1) Switch OFF and Remove the AC Power Socket from the outlet.   
(2) Remove the Black lead and then the Red lead.   

 

If the battery is still in the vehicle:   

(1) Switch OFF and Remove the AC Power Socket from the outlet.   
(2) Remove the lead from the vehicle chassis.   
(3) Remove the lead from the battery.   

Note: 

Check electrolyte levels if possible after charging as they may need topping up with distilled water. (This 

does not apply to sealed maintenance free batteries)

   

 

 

 

Содержание FULLOAD F12

Страница 1: ...FULLOAD F12 BATTERY CHARGER THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS ENGLISH ...

Страница 2: ...harger Take it to a qualified and authorized person for repair If using a generator you must ensure you use a surge protector to protect the charger from voltage spikes The charger must not be used or played with by infirm persons or children Also keep it away from any pets MAIN FEATURES 100 automatic smart battery charger maintainer with reconditioning function The battery charger is easy to use ...

Страница 3: ...e ERROR LED will light on and the charger will be disabled Simply unplug the charger from AC power and then connect the output leads to the correct polarity SHORT CIRCUIT PROTECTION The charger will automatically turn off if the output leads are short circuited and the ERROR LED will light on This prevents the charger from being damaged if the positive and negative crocodile clips or the optional ...

Страница 4: ...ery If the Battery is out of the vehicle Connect the Red Crocodile clip or optional ring terminal to the battery terminal Connect the Black Crocodile clip or optional ring terminal to the battery terminal If the battery is still in the vehicle determine if the vehicle is positively or negatively earthed If Negatively Earthed Most Common FIRST Connect the Red Crocodile clip or optional ring termina...

Страница 5: ...tion will stop the unit from charging and the Red Fault LED will start flashing and the Blue Bulk LED will be ON 5 Absorption Charging Green Absorption LED ON Uses a constant voltage while reducing the charging output current to ensure the battery receives a full charge without overcharging the battery 6 Equalization Charging Blue Bulk LED and Green Absorption LED both flashing A well proven proce...

Страница 6: ...ully charged Float Maintenance mode Absorption Green Flash ON Flashing during equalisation charging or ON during Absorption charging Bulk Blue Flash ON Fast Flash Rejuvenation Slow Flash Soft Start charging ON Bulk charging Error LED Red ON Short circuit reverse polarity or Rejuvenation failed if Bulk LED also flashing slow Red Flashing Over temperature protection mode Soft start charging timed ou...

Страница 7: ...urrent is only present when connected to a battery No charging current Error Red LED is Flashing Battery is severely sulphated Battery has a damaged cell Overheat protection mode Check the battery condition age etc Battery may need replacement Move battery charger to a cooler environment The full float light won t come on Error Red LED is Flashing or Full Charge Green LED is Flashing Battery Ah ca...

Страница 8: ...CHARGING CURVE ...

Страница 9: ...CHARGEUR DE BATTTERIE FULLOAD F12 NOTICE D UTILISATION ET CONSIGNES DE SÉCURITÉ POUR LE CHARGEUR DE BATTERIES FULLOADF12 FRANÇAIS ...

Страница 10: ...ique charge et maintien avec fonction de régénération Facile d utilisation le chargeur est facile à utiliser et ne nécessite aucune expérience technique Entièrement contrôlé par microprocesseur Diagnostic initial de la batterie à recharger Sécurité d inversion de polarité Régénération de la batterie améliorée technologie brevetée Analyse du rechargement de la batterie Impulsions de pointe pour l e...

Страница 11: ...les correctement Protection anti court circuit le chargeur va automatiquement s éteindre si les pinces font court circuit et la LED ERROR va s allumer Cela prémunit le chargeur des dégâts si les pinces crocodiles ou les connexions permanentes viennent à se toucher lorsque le chargeur est en marche Mode ÉCO ce chargeur a un mode intégré de fonctionnement économique Si le chargeur est branché à du c...

Страница 12: ...la batterie son type et sa capacité en ampère heure de manière à s assurer que le chargeur soit compatible Déterminer ensuite quels réglages de type de batterie et de taux de charge sélectionner sur le chargeur Assurez vous que la batterie se trouve dans un endroit bien ventilé et que le chargeur soit le plus loin possible de la batterie aussi loin que les câbles le permettent Étape 2 Connexion du...

Страница 13: ...entration en acide 3 Charge initiale lente La LED BULK clignote lentement en bleu Le chargeur délivre un courant réduit jusqu à ce que la batterie atteigne une tension de 11V Si la tension de 11V n est pas atteinte dans un délai de 6 h le compte à rebours de sécurité va stopper la charge et la LED rouge ERROR ainsi que la LED bleue BULK vont se mettre à clignoter 4 Charge principale LED BULK bleu ...

Страница 14: ... de taux de charge 1A 8A 12A Verte Allumée Indique le taux de charge sélectionné LED d état de charge BULK ABSORPTION FULL CHARGE FULL CHARGE Verte Clignotement All umée Clignote si l analyse échoue ou est allumée lorsque la batterie est complètement chargée Mode entretien long terme activé ABSORPTION Verte Clignotement All umée Clignote pendant la charge d égalisation ou allumée pendant la charge...

Страница 15: ...pas de courant La LED ERROR clignote La batterie est très sulfatée La batterie a une cellule endommagée La protection contre la surchauffe s est activée Vérifiez la condition de la batterie son âge etc La batterie pourrait avoir besoin d être remplacée Déplacez la batterie et le chargeur dans un endroit plus frais La LED FULL CHARGE ne s allume pas La LED ERROR rouge clignote ou la LED Full Charge...

Страница 16: ...ÉTAPES DE CHARGE ...

Отзывы: