Battery on the Calcium Battery Type setting as this may damage your battery and / or reduce your battery
life.
Note:
If the Fault Indicator LED illuminates Red, please check your connections as it’s likely that the Positive and
Negative Leads are reversed.
THE CHARGING PROCESS:
1) Qualification - Battery Condition Check
When the charger is first switched on it checks the battery condition to determine whether the battery needs
reconditioning. During this qualification process it checks the internal impedance and initial voltage of the
battery and it will determine how much charge current.
2) Enhanced Battery Rejuvenation - Blue Bulk LED Flashing Fast
If the initial qualification detected that the battery was in poor condition, the patented rejuvenation process
will begin automatically. During the rejuvenation process a high voltage equalizing and peak pulse
reconditioning charge is used to repair the sulphated battery. This unique patented feature will break down
and dissolve the lead-sulphate crystal build up on the battery plates which will extend the life of your battery.
It can also balance out high concentrations of acid.
3) Soft Start Charging - Blue Bulk LED Flashing Slow
Gently charges the battery using a reduced charge output until the battery voltages reaches 11V. If the battery
voltage doesn’t reach 11V within 6 hours, the safety timer protection will stop the unit from charging and the
Red Fault LED and Blue Bulk LED will start flashing.
4) Bulk Charging - Blue Bulk LED ON (Charge Voltage depends on battery type selection)
Charge with the maximum selected charge output until the battery voltage reaches 14.1/14.4/14.7V. If the
battery voltage doesn’t reach this within 24 hours, the safety timer protection will stop the unit from charging
and the Red Fault LED will start flashing and the Blue Bulk LED will be ON.
5) Absorption Charging - Green Absorption LED ON
Uses a constant voltage while reducing the charging output current to ensure the battery receives a full charge
without overcharging the battery.
6) Equalization Charging - Blue Bulk LED and Green Absorption LED both flashing
A well proven process that carefully overcharges the battery to restore it’s full capacity. The Equalization stage
for CALCIUM Battery type selection is automatic. The Equalization stage for AGM&WET and GEL Battery Types
only occurs if the initial start voltage is below 11 Volts.
7) Battery Analysis - Green Full LED ON
The battery analysis stage checks the condition of the battery after the charge cycle is completed. If the
battery voltage drops too quickly during the analysis mode, this means the battery is probably faulty. If the
battery analysis failed, this is indicated by the Green Full LED flashing.
8) Float Mode - Full Green LED ON
This stage allows you to keep the charger connected 24/7 to ensure your battery is well maintained and kept
100% fully charged. Float mode will maintain the battery at a constant 13.6V.
9) Long Term Maintenance - Full Green LED ON
During long term maintenance / float mode, the unit will apply a special pulse charge to ensure the battery is
kept in optimal condition.
STEP 4 - Disconnecting the Battery charger from Battery
If the Battery is out of the vehicle:
(1) Switch OFF and Remove the AC Power Socket from the outlet.
(2) Remove the Black lead and then the Red lead.
If the battery is still in the vehicle:
(1) Switch OFF and Remove the AC Power Socket from the outlet.
(2) Remove the lead from the vehicle chassis.
(3) Remove the lead from the battery.
Note:
Check electrolyte levels if possible after charging as they may need topping up with distilled water. (This
does not apply to sealed maintenance free batteries)