6-32
SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010
6.3.10
Removing the Tape Drive Backplane of the M5000
Server
Note –
The fan units and fan cage can be removed for increased visibility of the Tape
drive backplane if necessary.
1. Loosen the two (2) captive screws that secure the air baffle and slide the air
baffle towards the busbar to create working space to access the tape drive
backplane.
2. Remove the tape drive unit from the server and place it on the ESD mat.
See
Section 6.3.2, “Removing the Tape Drive Unit” on page 6-26
3. Disconnect the serial cable from the rear of the tape drive backplane.
4. Disconnect the power cable from the rear of the tape drive backplane.
5. Loosen the captive screw that secures the tape drive backplane in place.
6. Remove the tape drive backplane.
6.3.11
Installing the Tape Drive Backplane of the M5000
Server
1. Place the tape drive backplane into the server.
2. Tighten the captive screw that secures the tape drive backplane in place.
3. Secure the power cable to the tape drive backplane.
4. Secure the serial cable to the tape drive backplane.
Caution –
Do not force
the drive into a slot. Doing so can cause damage to the drive
and server.
5. Place the tape drive unit into the drive slot and gently push it in until it locks in
place.
6. Place the air baffle into position and tighten it in place using the two (2) captive
screws.
Note –
Be certain no cables are pinched beneath the air baffle when it is secured.
Содержание SPARC Enterprise M4000
Страница 4: ......
Страница 27: ...Chapter 2 Fault Isolation 2 3 FIGURE 2 2 Diagnostic Method Flow Chart Traditional Data Collection ...
Страница 62: ...2 38 SPARC Enterprise M4000 M5000 Servers Service Manual December 2010 ...
Страница 85: ...Chapter 5 Internal Components Access 5 3 FIGURE 5 1 Loosening the Captive Screws on the Shipping Brackets ...
Страница 89: ...Chapter 5 Internal Components Access 5 7 FIGURE 5 4 Removing the M5000 Server Top Cover ...
Страница 126: ...6 34 SPARC Enterprise M4000 M5000 Servers Service Manual December 2010 ...
Страница 132: ...7 6 SPARC Enterprise M4000 M5000 Servers Service Manual December 2010 ...
Страница 151: ...Chapter 8 I O Unit Replacement 8 19 FIGURE 8 12 Installing the DC DC Converter Without a DC DC Converter Retainer ...
Страница 155: ...Chapter 8 I O Unit Replacement 8 23 FIGURE 8 14 Removing the I O Unit DC DC Converter Riser and DC DC Converter DDC_B 0 ...
Страница 158: ...8 26 SPARC Enterprise M4000 M5000 Servers Service Manual December 2010 ...
Страница 179: ...Chapter 10 Fan Modules Replacement 10 15 FIGURE 10 6 Removing the M4000 Server 172 mm Fan Backplane ...
Страница 183: ...Chapter 10 Fan Modules Replacement 10 19 FIGURE 10 7 Removing the M5000 Server 172 mm Fan Backplane ...
Страница 221: ...Chapter 13 Motherboard Unit Replacement 13 9 FIGURE 13 4 Removing the M5000 Server Motherboard Unit ...
Страница 245: ...Chapter 14 Backplane Unit Replacement 14 11 FIGURE 14 4 Removing the M5000 Server Backplane ...
Страница 248: ...14 14 SPARC Enterprise M4000 M5000 Servers Service Manual December 2010 ...
Страница 254: ...15 6 SPARC Enterprise M4000 M5000 Servers Service Manual December 2010 FIGURE 15 3 Removing the Operator Panel ...
Страница 256: ...15 8 SPARC Enterprise M4000 M5000 Servers Service Manual December 2010 ...
Страница 288: ...E 6 SPARC Enterprise M4000 M5000 Servers Service Manual December 2010 ...
Страница 292: ...F 4 SPARC Enterprise M4000 M5000 Servers Service Manual December 2010 FIGURE F 2 Hook and Loop Tape Locations ...
Страница 303: ...Appendix F Air Filters F 15 11 Perform Steps 1 through 8 of Section F 1 1 Command Operations Procedures on page F 2 ...
Страница 304: ...F 16 SPARC Enterprise M4000 M5000 Servers Service Manual December 2010 ...
Страница 308: ...G 4 SPARC Enterprise M4000 M5000 Servers Service Manual December 2010 ...