User’s Guide
FUJITSU PSWITCH
December/2018
177
State
Ascending
Descending
Action
Level4
Shutdown
80℃~
75℃~
If the temperature exceeds over
85 ℃ , the device will shutdown
automatically.
Review the condition in/around the
device, improve the ventilation
condition of the device.
Level3
Critical
60℃~80℃
55℃~75℃
Check
the
environment
temperature,
if
it
does
not
complying with the operating
condition, take appropriate action
to meet the operating condition.
Review the condition in/around the
device, improve the ventilation
condition of the device.
Level2
Warning
45℃~60℃
40℃~55℃
No action is required.
This device may be in this state
when it is under high load or if the
environmental
temperature
exceeds 30℃.
Level1
Normal
30℃~45℃
25℃~40℃
No action is required.
IDLE
Low
~30℃
~25℃
No action is required.
Table 4-1: Transitions of Device Temperature