229
PRIMERGY TX300 S4 User’s Guide
Server Management Tools error messages
The following error messages may appear while executing Server Management Tools. In such cases,
perform the appropriate resolutions. If messages other than the following are displayed, contact an office
listed in the "Contact Information" of "Start Guide".
System Management Configuration
changed
Indicates an error of the hard disk configuration. Or the hard disk
configuration has changed. This message may be ignored if the hard
disk configuration has exactly changed. In case that no changes of
the hard disk configuration are performed, check the cable
connections. If the error message still appears although the cables
are connected properly, the affecting part(s) must be changed. Check
the system event log and what part has irregularities. Contact an
office listed in the "Contact Information" of "Start Guide".
table: List of Server Management Tools error message
Message
Description
Write protect error writing drive A.
Abort, Retry, Fail?
The inserted floppy disk is write-protected. Disable the
write-protect, and then press the [R] key.
Not ready writing drive A.
Abort, Retry, Fail?
A floppy disk is not inserted into the floppy disk drive.
Insert the proper floppy disk ("Server Management
Tools" disk), and then press the [R] key.
ERROR: Fail to create data file.
The following factors may be possibly root causes.
Check the floppy disk condition again.
• The floppy disk is write-protected. Disable the
write-protect and retry.
• The floppy disk is not inserted into the floppy disk
drive. Insert the proper floppy disk, and then retry.
• The floppy disk contains improper data. Create
"Server Management Tools" disk again. If this
occurs while recovering the BIOS information,
configure the information using BIOS Setup Utility.
Then store the BIOS information.
ERROR: Fail to write 1st CMOS data into data file. nn
ERROR: Fail to write 2nd CMOS data into data file. nn
ERROR: Fail to write ESCD data into the data file. nn
ERROR: Fail to write SEEPROM data into the data
file. nn
ERROR: Fail to open data file.
The file to recover the BIOS information does not exist
on this floppy disk. Insert the floppy disk on which the
BIOS information was stored, and then retry.
ERROR: Fail to write 1st CMOS data into system. nn
The following factors may be possibly root causes.
Check the floppy disk condition again.
• The floppy disk is not inserted into the floppy disk
drive. Insert the proper floppy disk, and then retry.
• This is a different model or an unsupported version
of BIOS information. Insert the proper floppy disk,
and then retry.
• The floppy disk contains improper data. Create
"Server Management Tools" again. If this occurs
while recovering BIOS information, configure the
information using BIOS Setup Utility. Then store
the BIOS information.
ERROR: Fail to write 2nd CMOS data into system file.
nn
ERROR: Fail to write ESCD data into system file. nn
ERROR: Fail to write SEEPROM data into system. nn
Other messages
Contact an office listed in the "Contact Information" of
"Start Guide".