156
Chapter 6 Installing Internal Options
6
Perform Installation/removal of memory modules on the memory board.
When installing memory modules
Open the levers on both sides of the slot, and insert the memory module. Insert the memory
module vertically to the slot by aligning notches of the memory module and memory slot
together. When the module is properly inserted, the levers on both sides will close. Ensure that
memory module is secured firmly. If the levers are not closed completely, push them to close.
When removing memory modules
Open the levers on both sides of the slot, and remove the memory module.
7
Install the memory board to the memory board slot.
8
Attach the ventilation duct.
To attach it, simply reverse the removal procedures.
9
Attach the side cover.
10
Initialize Extended System Configuration Data (ESCD).
On the [Advanced] menu in BIOS Setup Utility, set [Reset Configuration Data] to "Yes".
"7.2.5 Advanced Menu" (pg.199)
• If the memory module is not properly installed, it may cause a fire.
Insert the memory module in a correct direction.
• Do not open the levers swiftly. Otherwise, a memory module inside
may pop up and be damaged.
Lever
Align those notches.
Lever