TX150 S8 / TX200 S7
Upgrade and Maintenance Manual
95
Basic software procedures
Ê
Select the
Server Mgmt
menu.
Ê
Under
Boot Watchdog
set the
Action
setting to
Reset
.
Ê
Save your changes and exit the BIOS.
I
For detailed information on how to access the BIOS and modify settings,
refer to the corresponding BIOS Setup Utility reference manual.
Configuring boot watchdog settings using the iRMC web frontend
Ê
Enter the ServerView iRMC web frontend.
Ê
Select the
Server Management
menu.
Ê
Under
Watchdog Settings
ensure that the check box next to Boot Watchdog is
selected. From the drop down list choose
Reset
and specify the desired
timeout delay.
Ê
Click
Apply
for the changes to take effect.
I
For detailed information on iRMC settings, refer to the "Integrated
Remote Management Controller" user guides.
5.2.8
Enabling replaced components in the system BIOS
When a processor, an expansion card, or a memory module fails, the defective
component will be set to
Disabled
or
Failed
in the system BIOS. The server will
then reboot with only the intact hardware components remaining in the system
configuration. After replacing the defective component, it needs to be re-
enabled in the system board BIOS.
Ê
Enter the BIOS.
Ê
Select the
Advanced
menu.
Ê
Select the status menu of the desired component:
– Processors:
CPU Status
I
This option is only available for multi-processor systems.
– Memory:
Memory Status
– Expansion cards:
PCI Status
Ê
Reset replaced components to
Enable
.
Содержание PRIMERGY TX150 S8
Страница 22: ...Upgrade and Maintenance Manual TX150 S8 TX200 S7 Contents ...
Страница 108: ...108 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Basic software procedures ...
Страница 136: ...136 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Power supply units ...
Страница 184: ...184 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Hard disk drives solid state drives ...
Страница 196: ...196 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Fans ...
Страница 274: ...274 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Processors ...
Страница 348: ...348 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Front panel and external connectors ...
Страница 388: ...388 Upgrade and Maintenance Manual TX150 S8 TX200 S7 System board and components ...