
TX150 S8 / TX200 S7
Upgrade and Maintenance Manual
269
Processors
11.5.2.2 Installing the heat sink
Figure 186: Installing the heat sink
Ê
Align the heat sink as shown with the cooling fins matching the direction of
the airflow (see airflow label).
Ê
Carefully seat the heat sink on the four threaded holes as shown (see close-
up).
Ê
Fasten the four captive screws on the heat sink in a crossover pattern
(screw torque: 1.0 Nm, not applicable for the Japanese market) (1-4).
Содержание PRIMERGY TX150 S8
Страница 22: ...Upgrade and Maintenance Manual TX150 S8 TX200 S7 Contents ...
Страница 108: ...108 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Basic software procedures ...
Страница 136: ...136 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Power supply units ...
Страница 184: ...184 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Hard disk drives solid state drives ...
Страница 196: ...196 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Fans ...
Страница 274: ...274 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Processors ...
Страница 348: ...348 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Front panel and external connectors ...
Страница 388: ...388 Upgrade and Maintenance Manual TX150 S8 TX200 S7 System board and components ...