Important information
Wait until the device has acclimatized to room temperature and is absolutely
dry before starting it up. Material damage may be caused to the device if this
requirement is not observed.
●
Transport the device only in the original packaging or in packaging that
protects it from knocks and jolts.
For the Japanese market, transporting the device in its original packaging
does not apply.
Installation and operation
●
This unit should not be operated in ambient temperatures above 35 °C.
●
If the unit is integrated into an installation that draws power from an industrial
power supply network with an IEC309 connector, the power supply's fuse
protection must comply with the requirements for non-industrial power
supply networks for type A connectors.
●
The unit automatically adjusts itself to a mains voltage in a range of 100 V -
240 V. Ensure that the local mains voltage lies within these limits.
●
This device must only be connected to properly grounded power outlets or
connected to the grounded rack internal power distribution system with
tested and approved power cords.
●
Ensure that the device is connected to a properly grounded power outlet
close to the device.
●
Ensure that the power sockets on the device and the properly grounded
power outlets are easily accessible.
●
The On/Off button or the main power switch (if present) does not isolate the
device from the mains power supply. In case of repair or servicing
disconnect the device completely from the mains power supply, unplug all
power plugs from the properly grounded power outlets.
●
Always connect the server and the attached peripherals to the same power
circuit. Otherwise you run the risk of losing data if, for example, the server is
still running but a peripheral device (e.g. memory subsystem) fails during a
power outage.
●
Data cables must be adequately shielded.
●
Ethernet cabling has to comply with EN 50173 and EN 50174-1/2 standards
or ISO/IEC 11801 standard respectively. The minimum requirement is a
Category 5 shielded cable for 10/100 Ethernet, or a Category 5e cable for
Gigabit Ethernet.
Содержание PRIMERGY TX140 S2
Страница 30: ...30 Upgrade and Maintenance Manual TX140 S2 Before you start ...
Страница 98: ...98 Upgrade and Maintenance Manual TX140 S2 Basic software procedures ...
Страница 120: ...120 Upgrade and Maintenance Manual TX140 S2 Power supply ...
Страница 148: ...148 Upgrade and Maintenance Manual TX140 S2 Hard disk drives solid state drives ...
Страница 158: ...158 Upgrade and Maintenance Manual TX140 S2 System fan and air duct ...
Страница 208: ...208 Upgrade and Maintenance Manual TX140 S2 Expansion cards and backup units ...
Страница 216: ...216 Upgrade and Maintenance Manual TX140 S2 Main memory ...
Страница 314: ...314 Upgrade and Maintenance Manual TX140 S2 Cabling ...
Страница 332: ...332 Upgrade and Maintenance Manual TX140 S2 Appendix ...