221
PRIMERGY TX120 User’s Guide
9
Op
eration
a
nd
Mainten
ance
Message Recorded on System Event Log (SEL)
The following messages may be recorded when System Event Log (SEL) is displayed using ServerView
supplied with the server or Server Management Tools.
This message shows that restart process of Remote Management Controller (iRMC) installed on the
server systemboard by default has been executed. It is not a problem for the continuous server operation.
• Message displayed by ServerView
• Message displayed by Server Management Tools
Server Management Tools Error Messages
The following error messages may appear while executing Server Management Tools. In such cases,
perform the corresponding resolutions. If messages other than the following are displayed, contact an
office listed in the "Contact Information" of "Start Guide".
iRMC reports sensor status: CRITICAL FAN1
SYS
System fan 1 or 2 error.
Check whether there are any obstacles interfering with the
rotation of the system fan. If the message still appears, the
system fan or baseboard must be replaced. Contact an office
listed in the "Contact Information" of "Start Guide".
iRMC reports sensor status: CRITICAL FAN2
SYS
RMC reports sensor status: CRITICAL FAN
PSU
PSU fan error.
Check whether there are any obstacles interfering with the
rotation of the PSU fan. If the message still appears, the PSU
fan or baseboard must be replaced. Contact an office listed in
the "Contact Information" of "Start Guide".
Controller access degraded or unavailable
ControllerAccessDegradedOrUnavailable-Asserted
table: List of Server Management Tools Error Messages
Message
Description
Write protect error writing drive A.
Abort, Retry, Fail?
The inserted floppy disk is write-protected. Disable the
write-protect, and then press the [R] key.
Not ready writing drive A.
Abort, Retry, Fail?
The floppy disk is not inserted into the floppy disk
drive. Insert the proper floppy disk ("Server
Management Tools" disk), and then press the [R] key.
ERROR:Fail to create data file.
The following are possible causes. Check the floppy
disk status again.
• The floppy disk is write-protected. Disable the
write-protect and retry.
• The floppy disk is not inserted into the floppy disk
drive. Insert the proper floppy disk, and then retry.
• There is an error in the contents of the floppy disk.
Create "Server Management Tools" again. If this
occurred while recovering BIOS information,
configure the information using the BIOS Setup
Utility. Then store the BIOS information.
ERROR:Fail to write 1st CMOS data into data file. nn
ERROR:Fail to write 2nd CMOS data into data file. nn
ERROR:Fail to write ESCD data into the data file. nn
ERROR:Fail to write SEEPROM data into the data file.
nn
ERROR:Fail to open data file.
The file for recovering the BIOS information does not
exist on this floppy disk. Insert the floppy disk on
which the BIOS information was stored, and then retry.
table: List of POST Errors
Message
Description
Содержание Primergy TX120
Страница 6: ...6 ...
Страница 12: ...12 ...
Страница 62: ...62 Chapter 3 OS Installation Using ServerStart 6 Set items and click Next The Network Protocol window appears ...
Страница 122: ...122 Chapter 4 Manual OS Installation ...
Страница 152: ...152 Chapter 5 Operations after OS Installation ...
Страница 188: ...188 Chapter 7 Installing Hardware Options ...
Страница 210: ...210 Chapter 8 Configuring Hardware and Utilities ...
Страница 262: ...262 ...