210
Chapter 7 Installing Internal Options
To use the remote service board, ServerView is required. Be sure to install it. For how to install
ServerView, refer to "6.2 Server Monitoring Tool [ServerView]" (
pg.173). For the remote service
board functions, refer to "ServerView User's Guide."
When the remote service board is connected, the monitor brightness may become lower. In this case,
adjust the monitor for higher brightness.
The recommended screen refresh rate for the monitor is 70Hz. In case of poor resolution of the
monitor display, set the screen refresh rate to 70Hz.
7.5.3 How to Install Expansion Cards
1
Turn off the server and connected devices, and unplug all power cables from
the outlet.
2
Remove the top cover.
"7.2 Removing and Attaching the Top Cover" (pg.180)
3
Touch a metal part of the server to discharge static electricity.
4
Rotate the retention latch to the up position and remove the slot cover.
When installing a card in Slot 1 through 5, rotate the PCI card holder retention plate and latch
into the up position and pull up the PCI card holder at its handle to remove it.
Be sure to keep the removed slot cover or dummy cards for later use.
If operating the server with no expansion card, attach the slot cover to keep out dust.
PCI card holder
Latch
Handle
Plate
Содержание Primergy RX600 S2
Страница 6: ...6 ...
Страница 68: ...68 Chapter 3 OS Installation Using ServerStart 6 Set items and click Next The Network Protocol window appears ...
Страница 110: ...110 Chapter 3 OS Installation Using ServerStart ...
Страница 132: ...132 Chapter 4 Manual OS Installation ...
Страница 228: ...228 Chapter 7 Installing Internal Options ...
Страница 286: ...286 Chapter 9 Operation and Maintenance ...
Страница 298: ...298 ...