Appendix
The LEDs have the following meaning:
LED Indicator
Meaning
A - CSS
(Customer Self
Service)
off
no error (CSS component)
orange on
indicates a prefailure (CSS component)
orange flashing indicates a failure (CSS component)
B - GEL
(Global Error
LED)
off
no error (non CSS component)
orange on
indicates a prefailure (non CSS
component)
orange flashing indicates a failure of a non CSS
component.
Reasons for a failure may be:
– over temperature measured by one of
the sensors
– sensor is defective
– CPU error
– software detected an error
C - Identification blue on
server has been highlighted using iRMC
web frontend, ServerView Operations
Manager or the ID button on the front
panel for easy identification
blue flashing
local monitor off
D - Memory
off
memory module running
orange on
memory module failure
E - AUX power
off
orange on
voltages okay
F - System fan
off
system fan running
orange on
system fan failure
G - PCI card
off
PCI card okay
orange on
PCI card failure (PCI card installed on riser
card)
H - iRMC
off
iRMC S4 inactive
green flashing
iRMC S4 okay
Содержание PRIMERGY RX1330 M1
Страница 62: ...62 Upgrade and Maintenance Manual RX1330 M1 Basic hardware procedures ...
Страница 150: ...150 Upgrade and Maintenance Manual RX1330 M1 Hard disk drives solid state drives ...
Страница 156: ...156 Upgrade and Maintenance Manual RX1330 M1 Fans ...
Страница 204: ...204 Upgrade and Maintenance Manual RX1330 M1 Expansion cards and backup units ...
Страница 234: ...234 Upgrade and Maintenance Manual RX1330 M1 Optical disk drive ...
Страница 312: ...312 Upgrade and Maintenance Manual RX1330 M1 Appendix ...