Hard disk drives / solid state drives
In order to permanently remove an operational HDD module that is part of a
RAID array from the server, you first need to delete the array using
ServerView RAID Manager.
V
CAUTION!
All data on all HDDs/SSDs in the array will be lost! Be sure to back up
your data before deleting a RAID array.
For further information, please refer to the "ServerView Suite RAID
Management" user guide.
7.2.6.2
Removing a 2.5-inch HDD/SSD module
Ê
Pinch the green locking clips and open the locking lever (see figure
56
).
Ê
Pull the HDD/SSD module out a few centimeters.
Ê
Wait about 30 seconds to allow the hard disk drive to spin down.
I
This is not necessary when removing a solid state drive.
I
This period is necessary for the RAID controller to recognize that an
HDD module has been removed and for the hard disk drive to come
to a stop.
Ê
Pull the HDD/SSD module completely out of its bay.
RAID 1
RAID 5
Removing an HDD module from a RAID 1 or RAID 5 array
will not result in data loss.
However, the removed drive needs to be replaced
immediately by an HDD module of the same or larger
capacity.
I
After replacing the HDD module, RAID rebuild will
be performed as a background process as
described in section
"Performing a RAID array
rebuild" on page 85
.
RAID level Procedure
Содержание PRIMERGY RX1330 M1
Страница 62: ...62 Upgrade and Maintenance Manual RX1330 M1 Basic hardware procedures ...
Страница 150: ...150 Upgrade and Maintenance Manual RX1330 M1 Hard disk drives solid state drives ...
Страница 156: ...156 Upgrade and Maintenance Manual RX1330 M1 Fans ...
Страница 204: ...204 Upgrade and Maintenance Manual RX1330 M1 Expansion cards and backup units ...
Страница 234: ...234 Upgrade and Maintenance Manual RX1330 M1 Optical disk drive ...
Страница 312: ...312 Upgrade and Maintenance Manual RX1330 M1 Appendix ...