140
Upgrade and Maintenance Manual
RX1330
M1
Hard disk drives / solid state drives
Ê
Connect the SAS cables:
The shorter SAS cable connected to HDD backplane (A3C40157828) to
connector "MLC1" of the dual-channel RAID controller (1)
The longer SAS cable connected to HDD backplane (A3C40157852) to
connector "MLC2" of the dual-channel RAID controller (2)
Figure 75: Routing SAS cables
Ê
Route the SAS cables as shown in the figure above.
7.2.11.3 Installing additional HDD/SSD modules
Ê
Remove the dummy locks as described in section
"Removing a 2.5-inch
HDD/SSD dummy module" on page 120
.
Ê
Move the HDD/SSD modules installed in the former HDD bays 1 to 4 (see
figure
48
) to the new HDD bays 1 to 4 (see figure
50
).
Ê
Insert additional HDD/SSD modules as described in section
"Installing 2.5-
inch HDD/SSD modules" on page 120
.
7.2.11.4 Concluding steps
Ê
"Reassembling" on page 52
Ê
"Connecting the server to the mains" on page 55
Ê
"Switching on the server" on page 57
Ê
"Performing a RAID array rebuild" on page 85
MLC 2
MLC 1
Содержание PRIMERGY RX1330 M1
Страница 62: ...62 Upgrade and Maintenance Manual RX1330 M1 Basic hardware procedures ...
Страница 150: ...150 Upgrade and Maintenance Manual RX1330 M1 Hard disk drives solid state drives ...
Страница 156: ...156 Upgrade and Maintenance Manual RX1330 M1 Fans ...
Страница 204: ...204 Upgrade and Maintenance Manual RX1330 M1 Expansion cards and backup units ...
Страница 234: ...234 Upgrade and Maintenance Manual RX1330 M1 Optical disk drive ...
Страница 312: ...312 Upgrade and Maintenance Manual RX1330 M1 Appendix ...