RX1330 M1
Upgrade and Maintenance Manual
201
Expansion cards and backup units
9.5.5.3
Installing the new BBU
Ê
Connect the BBU cable to the BBU and install the BBU in the holder as
described in section
"Preparing the BBU" on page 187
.
Ê
Install the BBU with the holder as described in section
"Installing the BBU"
on page 189
.
9.5.5.4
Concluding steps
Ê
"Reassembling" on page 52
Ê
"Connecting the server to the mains" on page 55
Ê
"Updating RAID controller firmware" on page 74
Ê
"Enabling SVOM boot watchdog functionality" on page 78
Ê
"Switching on the server" on page 57
Note on BBU charging and calibration
The BBU may be deeply discharged due to extended storage time and wrongly
show as bad or defective in the ServerView RAID Manager.
In this case, the BBU will automatically enter a trickle charge cycle for recovery.
This initial charge may take up to 12 hours before the BBU will initiate a
recalibration cycle.
Ê
Enter the ServerView RAID Manager and check the current BBU status.
I
For further information, please refer to the "ServerView Suite RAID
Management" user guide.
Ê
If the BBU is shown as bad or defective, do not power off the server for at
least 12 hours to allow the charge and calibration cycles to finish.
Ê
If the BBU status does not change after 12 hours, please try to initiate the
recalibration process manually using the ServerView RAID Manager.
I
If this procedure still does not fix the BBU status, please contact your
local Fujitsu customer service partner.
Содержание PRIMERGY RX1330 M1
Страница 62: ...62 Upgrade and Maintenance Manual RX1330 M1 Basic hardware procedures ...
Страница 150: ...150 Upgrade and Maintenance Manual RX1330 M1 Hard disk drives solid state drives ...
Страница 156: ...156 Upgrade and Maintenance Manual RX1330 M1 Fans ...
Страница 204: ...204 Upgrade and Maintenance Manual RX1330 M1 Expansion cards and backup units ...
Страница 234: ...234 Upgrade and Maintenance Manual RX1330 M1 Optical disk drive ...
Страница 312: ...312 Upgrade and Maintenance Manual RX1330 M1 Appendix ...