102
Upgrade and Maintenance Manual
RX1330
M1
Power supply
6.3.2.1
Preliminary steps
No steps needed.
6.3.2.2
Removing a hot-plug power supply unit
Ê
Remove the power cord from the dedicated power supply unit as described
in section
"Disconnecting the server from the mains" on page 46
.
Figure 34: Unlocking and removing the hot-plug power supply unit
Ê
Push the handle of the power supply unit halfway upward in the direction of
the arrow (1).
Ê
Push the lock in direction of the arrow (2).
Ê
Grip the handle and pull out the power supply unit in the direction of the
arrow (3).
V
CAUTION!
Never leave the bay for the power supply unit empty for more than two
minutes during operation. Otherwise, excessive temperatures could
damage system components.