262
Upgrade and Maintenance Manual
BX924
S3
System board components
10.3.3 Replacing the TPM
V
CAUTION!
Advise your contact persons that they must provide you with TPM
backup copies. For security reasons, the TPM must be restored/re-
saved by the customer. After installing a new system board, the TPM
must be enabled. You may not clear the TPM data.
If the contact persons
DO NOT
have a backup copy available, inform
them that replacing the TPM will cause to lose all data.
10.3.3.1 Required tools
●
Preliminary and concluding steps: tool-less
●
Removing the system board:
– Phillips PH2 / (+) No. 2 screw driver
●
Replacing the TPM:
– Bit screw driver
– TPM bit insert
(
*
)
– thin slotted screw driver (
2 x 0.4 mm)
(
*
)
(
*
)
For the Japanese market:
– Dedicated TPM screw driver (CWZ8291A)
– TPM module fixing tool (S26361-F3552-L909)
Field Replaceable Units (FRU)
Average task duration: 40 minutes
Содержание PRIMERGY BX924 S3
Страница 6: ...Upgrade and Maintenance Manual BX924 S3 ...
Страница 16: ...16 Upgrade and Maintenance Manual BX924 S3 ...
Страница 20: ...20 Upgrade and Maintenance Manual BX924 S3 Introduction ...
Страница 42: ...42 Upgrade and Maintenance Manual BX924 S3 Important information ...
Страница 68: ...68 Upgrade and Maintenance Manual BX924 S3 Basic hardware procedures ...
Страница 104: ...104 Upgrade and Maintenance Manual BX924 S3 Basic software procedures ...
Страница 180: ...180 Upgrade and Maintenance Manual BX924 S3 Main memory ...
Страница 199: ...BX924 S3 Upgrade and Maintenance Manual 199 Processors Figure 71 Opening the load plate B Ê Fully open the load plate ...
Страница 211: ...BX924 S3 Upgrade and Maintenance Manual 211 Processors Figure 81 Opening the load plate B Ê Fully open the load plate ...
Страница 232: ...232 Upgrade and Maintenance Manual BX924 S3 Processors ...
Страница 278: ...278 Upgrade and Maintenance Manual BX924 S3 System board components ...