122
Upgrade and Maintenance Manual
BX924
S3
Solid state drives
6.5
Replacing an SSD module
V
CAUTION!
●
All SSD modules (drives) must be uniquely identified so that they can
be reinstalled in their original mounting locations later. If this is not
done, existing data can be lost.
6.5.1
Required tools
●
Preliminary and concluding steps: tool-less
●
Replacing an SSD module: Phillips PH2 / (+) No. 2 screw driver
6.5.2
Preliminary steps
Before replacing an SSD module, perform the following steps:
Ê
Disable BitLocker functionality as described in section
"Disabling BitLocker
functionality" on page 73
.
Ê
If applicable, open the rack door as described in section
"Opening the rack
door" on page 53
.
Ê
Locate the desired server blade as described in section
"Locating the
defective server blade" on page 45
.
Ê
Shut down the server blade as described in section
"Shutting down the
server blade" on page 54
.
Ê
Remove the server blade from the system unit as described in section
"Removing the server blade from the system unit" on page 59
.
Ê
Open the server blade as described in section
"Opening the server blade"
on page 60
.
Upgrade and Repair Units (URU)
Average hardware task duration: 15 minutes
Average software task duration: 5 minutes
Содержание PRIMERGY BX924 S3
Страница 6: ...Upgrade and Maintenance Manual BX924 S3 ...
Страница 16: ...16 Upgrade and Maintenance Manual BX924 S3 ...
Страница 20: ...20 Upgrade and Maintenance Manual BX924 S3 Introduction ...
Страница 42: ...42 Upgrade and Maintenance Manual BX924 S3 Important information ...
Страница 68: ...68 Upgrade and Maintenance Manual BX924 S3 Basic hardware procedures ...
Страница 104: ...104 Upgrade and Maintenance Manual BX924 S3 Basic software procedures ...
Страница 180: ...180 Upgrade and Maintenance Manual BX924 S3 Main memory ...
Страница 199: ...BX924 S3 Upgrade and Maintenance Manual 199 Processors Figure 71 Opening the load plate B Ê Fully open the load plate ...
Страница 211: ...BX924 S3 Upgrade and Maintenance Manual 211 Processors Figure 81 Opening the load plate B Ê Fully open the load plate ...
Страница 232: ...232 Upgrade and Maintenance Manual BX924 S3 Processors ...
Страница 278: ...278 Upgrade and Maintenance Manual BX924 S3 System board components ...