5 - 18
5.6.4
Setting parameters
The user can specify the optimal operation mode for the user system environments by setting
the following parameters with the MODE SELECT or MODE SELECT EXTENDED
command:
•
Error recovery parameter
•
Disconnection/reconnection parameter
•
Caching parameter
•
Control mode parameter
With the MODE SELECT or MODE SELECT EXTENDED command, specify 1 for the "SP"
bit on CDB to save the specified parameter value on the disk. This enables the IDD to operate
by using the parameter value set by the user when power is turned on again. When the system
has more than one INIT, different parameter value can be set for each INIT.
When the parameters are not set or saved with the MODE SELECT or MODE SELECT
EXTENDED command, the IDD sets the default values for parameters and operates when
power is turned on or after reset. Although the IDD operations are assured with the default
values, the operations are not always optimal for the system. To obtain the best performance,
set the parameters in consideration of the system requirements specific to the user.
This section outlines the parameter setting procedures. Refer to Chapter 3 of SCSI Logical
Interface Specifications for further details of the MODE SELECT and MODE SELECT
EXTENDED commands and specifying the parameters.
IMPORTANT
1.
At factory shipment of the IDD, the saving operation for the MODE
SELECT parameter is not executed. So, if the user does not set
parameters, the IDD operates according to the default value of each
parameter
2.
The model select parameter is not saved for each SCSI ID of but as
the common parameter for all IDs. In the multi-INIT System,
parameter setting cannot be changed for each INIT.
3.
Once parameters are saved, the saved value is effective as long as
next saving operation is executed from the INIT. For example, even if
the initialization of the disk is performed by the FORMAT UNIT
command, the saved value of parameters described in this section is
not affected.
4.
When the IDD, to which the saving operation has been executed on a
system, is connected to another system, the user must pay attention to
that the IDD operates according to the saved parameter value if the
saving operation is not executed at installation.
Содержание MAE3091LC SERIES
Страница 3: ...This page is intentionally left blank ...
Страница 11: ...This page is intentionally left blank ...
Страница 23: ...C141 E064 03EN 1 6 Figure 1 2 MAF series LP MP outer view Figure 1 3 MAE series LC outer view ...
Страница 29: ...This page is intentionally left blank ...
Страница 37: ...This page is intentionally left blank ...
Страница 55: ...C141 E064 03EN 4 2 Figure 4 1 External dimensions MAF series LC MC ...
Страница 56: ...C141 E064 03EN 4 3 Figure 4 2 External dimensions MAF series LP MP ...
Страница 57: ...C141 E064 03EN 4 4 Figure 4 3 External dimensions MAE series LC ...
Страница 58: ...C141 E064 03EN 4 5 Figure 4 4 External dimensions MAE series LP ...
Страница 59: ...C141 E064 03EN 4 6 Figure 4 5 External dimensions MAG series LC MC ...
Страница 60: ...C141 E064 03EN 4 7 Figure 4 6 External dimensions MAG series LP MP ...
Страница 72: ...C141 E064 03EN 4 19 Figure 4 22 External operator panel connector CN2 ...
Страница 83: ...This page is intentionally left blank ...
Страница 87: ...C141 E064 03EN 5 4 3 Connecting more than one IDD multi host Figure 5 1 SCSI bus connections 2 of 2 ...
Страница 97: ...C141 E064 03EN 5 14 Motor starts when power is turned on Figure 5 4 Checking the SCSI connection A 60 ...
Страница 117: ...This page is intentionally left blank ...
Страница 118: ...C141 E064 03EN B 1 APPENDIX B SETTING TERMINALS B 1 Setting Terminals This appendix describes setting terminals ...
Страница 121: ...This page is intentionally left blank ...
Страница 125: ...This page is intenitionally left blank ...
Страница 133: ......