C141-E064-03EN
4 - 15
(4)
Sequential starting of spindle motors
After power is turned on to the IDD, a large amount of current flows in the +12 VDC line
when the spindle motor rotation starts. Therefore, if more than one IDD is used, the spindle
motors should be started sequentially using one of the following procedures to prevent
overload of the power supply unit. For how to set a spindle motor start control mode, see
Subsection 5.3.2.
a) Issue START/STOP commands at more than 12-second intervals to start the spindle
motors. For details of this command specification, refer to SCSI Logical Interface
Specifications.
b) Turn on the +12 VDC power in the power supply unit at more than 12-second intervals to
start the spindle motors sequentially.
(5)
Power supply to SCSI terminating resistor
If power for the terminating resistor is supplied from the IDD to other SCSI devices through
the SCSI bus, the current-carrying capacity of the +5 VDC power supply line to the IDD must
be designed with considering of an increase of up to 200 mA.
A method of power supply to the terminating resistor is selected with a setting terminal on the
IDD. See Subsection 5.3.2 for this selection.
For the electrical condition of supplying power to the terminating resistor, refer to Subsection
1.4.2 in SCSI Physical Interface Specifications.
(6)
Noise filter
To eliminate AC line noise, a noise filter should be installed at the AC input terminal on the
IDD power supply unit. The specification of this noise filter is as follows:
•
Attenuation: 40 dB or more at 10 MHz
•
Circuit construction: T-configuration as shown in Figure 4.17 is recommended.
Figure 4.17 AC noise filter (recommended)
Содержание MAE3091LC SERIES
Страница 3: ...This page is intentionally left blank ...
Страница 11: ...This page is intentionally left blank ...
Страница 23: ...C141 E064 03EN 1 6 Figure 1 2 MAF series LP MP outer view Figure 1 3 MAE series LC outer view ...
Страница 29: ...This page is intentionally left blank ...
Страница 37: ...This page is intentionally left blank ...
Страница 55: ...C141 E064 03EN 4 2 Figure 4 1 External dimensions MAF series LC MC ...
Страница 56: ...C141 E064 03EN 4 3 Figure 4 2 External dimensions MAF series LP MP ...
Страница 57: ...C141 E064 03EN 4 4 Figure 4 3 External dimensions MAE series LC ...
Страница 58: ...C141 E064 03EN 4 5 Figure 4 4 External dimensions MAE series LP ...
Страница 59: ...C141 E064 03EN 4 6 Figure 4 5 External dimensions MAG series LC MC ...
Страница 60: ...C141 E064 03EN 4 7 Figure 4 6 External dimensions MAG series LP MP ...
Страница 72: ...C141 E064 03EN 4 19 Figure 4 22 External operator panel connector CN2 ...
Страница 83: ...This page is intentionally left blank ...
Страница 87: ...C141 E064 03EN 5 4 3 Connecting more than one IDD multi host Figure 5 1 SCSI bus connections 2 of 2 ...
Страница 97: ...C141 E064 03EN 5 14 Motor starts when power is turned on Figure 5 4 Checking the SCSI connection A 60 ...
Страница 117: ...This page is intentionally left blank ...
Страница 118: ...C141 E064 03EN B 1 APPENDIX B SETTING TERMINALS B 1 Setting Terminals This appendix describes setting terminals ...
Страница 121: ...This page is intentionally left blank ...
Страница 125: ...This page is intenitionally left blank ...
Страница 133: ......