Table
3-15
Problems
resolved
in
XCP
2090
(continued)
SPARC
M10-
RTI
No.
1
4
4S
Description
Workaround
RTIF2-
131213-017
x
x
x
Any
of
the
following
may
occur
while
XSCF
is
running.
[Symptom1]
Process
down
occurs
and
XSCF
resets.
[Symptom2]
Response
of
commands
which
deals
with
acquiring
MIB
information
(get
command,
etc.)
becomes
slow.
[Symptom3]
Execution
of
commands
like
showhardconf(8)
takes
time.
Moreover,
when
the
showhardconf(8)
command
is
executed,
the
following
message
may
be
output
and
the
command
is
terminated
abnormally.
"Cannot
communicate
with
the
other
XSCF.
Check
the
other
XSCF'
stat"
[Symptom
4]
The
"SCF
panic
detected"
error
is
produced
and
the
XSCF
is
reset.
[Symptom
5]
Login
to
XSCF
Web
fails.
However,
login
to
the
XSCF
shell
is
possible.
There
is
no
effective
workaround.
[How
to
restore]
-
For
symptoms
1,
2,
and
4:
The
system
can
be
recovered
by
resetting
XSCF.
The
system
can
be
used
after
that.
-
For
symptom
3
and
5:
Reset
XSCF
with
the
rebootxscf(8)
command.
RTIF2-
131213-018
x
x
x
If
XSCF
has
disabled
the
setup
of
NTP
client,
the
time
difference
between
XSCF
and
the
hypervisor
of
each
physical
partition
(PPAR)
is
mistakenly
updated
and
the
time
of
the
logical
domain
may
be
misaligned
after
PPAR
is
rebooted.
Enable
the
NTP
client
setup
of
XSCF
by
executing
the
"setntp
-s
client
-c
enable"
command
and
synchronize
XSCF
with
the
upper
level
NTP
server.
Otherwise,
execute
the
following.
1.
Execute
the
showdateoffset(8)
command
before
powering
on
or
rebooting
the
PPAR
and
confirm
the
time
difference
between
XSCF
and
the
hypervisor.
2.
If
the
time
difference
is
too
large,
execute
the
resetdateoffset(8)
command
with
the
PPAR
at
stopped
state,
in
order
to
reset
the
time
difference.
3.
After
powering
on
the
PPAR,
reset
the
time
of
Solaris
OS.
RTIF2-
131213-020
x
x
x
Due
to
the
retry
functionality
of
XSCF,
if
any
abnormality
occurs
in
the
recoverable
backup
memory
inside
the
PSU
backplane
(PSUBP)
for
more
than
three
times,
XSCF
regards
it
wrongly
as
a
fixed
error
and
the
starting
of
XSCF
may
be
deterred.
In
such
a
case,
the
"REBOOT:
COUNTER
ERROR"
message
is
displayed.
There
is
no
effective
workaround.
[How
to
restore]
Re-execute
power
off
and
on.
Chapter
3
Information
on
Software
123
Содержание M10 Series
Страница 8: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 viii ...
Страница 14: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 xiv ...
Страница 24: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 10 ...
Страница 192: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 178 ...
Страница 200: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 186 ...