Table
3-15
Problems
resolved
in
XCP
2090
(continued)
SPARC
M10-
RTI
No.
1
4
4S
Description
Workaround
RTIF2-
131126-002
x
If
one
of
BB#0/BB#01/XBBOX#80/
XBBOX#81
is
installed
or
replaced,
the
synchronous
processing
of
the
CPU
core
activation
key
in
the
master/standby
XSCF
will
fail.
Subsequently,
if
the
master
and
standby
are
switched,
the
CPU
core
activation
key
may
be
lost.
This
generates
the
following
phenomena.
[If
the
PPAR
power
is
on]
The
PPAR
power
is
powered
off
because
of
a
CPU
core
activation
violation.
[If
the
PPAR
power
is
off]
PPAR
power-on
fails
because
there
is
an
insufficient
number
of
CPU
core
activations.
After
installation/replacement,
the
synchronous
processing
of
the
CPU
core
activation
keys
is
performed
when
the
following
is
executed.
-
If
the
master/standby
XSCF
is
not
switched
Execute
the
rebootxscf
-a
or
addcodactivation(8)
command
from
the
master
XSCF
that
requested
installation/replacement.
-
If
the
master/standby
XSCF
has
been
switched
Execute
the
switchscf(8)
command
to
return
the
master
XSCF
to
the
pre-installation/replacement
state.
After
that,
execute
the
rebootxscf
-a
or
addcodactivation(8)
command.
Note
-
Do
not
perform
the
following
operations
before
restoring
the
master
XSCF
to
its
original
state
by
executing
the
switchscf(8)
command.
If
these
operations
are
performed,
it
may
be
necessary
to
register
the
CPU
core
activation
key
again.
-
rebootxscf
-a
-
addcodactivation(8)
-
deletecodactivation(8)
-
Input
power
off/on
RTIF2-
131126-004
x
x
x
When
the
firmware
update
of
the
PCI
expansion
unit
and
link
card
is
complete,
the
firmware
version
of
the
PCI
expansion
unit
is
erroneously
displayed.
Specifically,
"PCIBOX
version"
of
the
event
log
displays
the
pre-update
version,
while
"last
version"
displays
the
post-update
version.
[Example]
Version
displayed
after
an
update
from
1120
to
1130
-
Incorrect:
LINKCARD=1,
bank=1,
PCIBOX
version=1120:
last
version=1130
-
Correct:
LINKCARD=1,
bank=1,
PCIBOX
version=1130:
last
version=1120
There
is
no
effective
workaround.
Replace
the
version
number.
Moreover,
update
the
XCP
firmware
to
XCP
2090
or
later.
Chapter
3
Information
on
Software
121
Содержание M10 Series
Страница 8: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 viii ...
Страница 14: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 xiv ...
Страница 24: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 10 ...
Страница 192: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 178 ...
Страница 200: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 186 ...