Table
3-6
Problems
resolved
in
XCP
2240
(continued)
SPARC
M10-
RTINo.
1
4
4S
Description
Workaround
RTIF2-
140507-013
x
x
x
Even
if
two
default
gateways
are
set
up
using
the
setroute(8)
command,
connection
from
other
networks
is
possible
only
on
either
XSCF-LAN#0
or
XSCF-LAN#1.
Among
XSCF-LAN#0
and
XSCF-LAN#1,
use
the
IP
address
of
the
gateway
that
can
be
connected
to.
RTIF2-
140515-001
x
In
order
to
configure
the
XSCF
startup
mode
function,
after
changing
the
startup
mode
with
the
xscfstartupmode(8)
command
or
setting
the
operation
panel
mode
switch
to
"Locked"
or
"Service",
if
the
rebootxscf(8)
command
is
executed
to
reset
XSCF,
the
new
startup
mode
gets
enabled.
However,
under
normal
circumstances,
the
configuration
of
the
startup
mode
is
not
enabled
when
XSCF
is
reset
using
the
rebootxscf(8)
command.
It
is
enabled
only
when
the
input
power
of
the
system
is
turned
off/on
(AC
OFF/ON).This
state
can
be
confirmed
by
the
"xscfstartupmode
-d"
command,
as
follows:
[Example]
When
startup
mode
is
set
to
"fast"
after
setting
the
operation
panel
mode
switch
to
"Locked"
XSCF>
xscfstartupmode
-d
Setting
Mode:
normal
Current
Mode:
normal
XSCF>
xscfstartupmode
-m
fast
XSCF>
rebootxscf
-a
XSCF>
xscfstartupmode
-d
Setting
Mode:
fast[need
AC
OFF/ON]
Current
Mode:
fast
However,
the
correct
result
will
be
that
the
"Current
Mode"
be
"normal"
like
the
following:
XSCF>
xscfstartupmode
-d
Setting
Mode:
fast
[need
AC
OFF/ON]
Current
Mode:
normal
There
is
no
effective
workaround.
RTIF2-
140523-001
x
In
the
event
of
an
instantaneous
power
failure
lasting
11
ms
or
more,
the
CHECK
LED
on
the
operation
panel
will
remain
on
after
recovery,
and
the
XSCF
may
not
start.
Therefore,
even
if
the
system
is
set
to
automatically
start
after
recovery,
it
may
not
actually
start
automatically.
There
is
no
effective
workaround.
[How
to
restore]
After
turning
off
the
input
power,
wait
for
at
least
10
seconds
before
turning
it
on
again.
Fujitsu
M10/SPARC
M10
Systems
Product
Notes
for
XCP
Version
2240
・
March
2015
84
Содержание M10 Series
Страница 8: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 viii ...
Страница 14: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 xiv ...
Страница 24: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 10 ...
Страница 192: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 178 ...
Страница 200: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 186 ...