Table
3-21
Problems
resolved
in
versions
prior
to
XCP
2050
(continued)
SPARC
M10-
RTI
No.
1
4
4S
Description
Workaround
RTIF2-
121113-025
x
x
x
When
a
CPU
failure
occurs,
an
error
message
showing
degradation
or
offline
on
Oracle
Solaris
may
not
be
output
to
Syslog.
Use
the
showlogs(8)
command
to
check
a
failure
state
on
XSCF.
RTIF2-
121113-027
x
x
x
If
you
update
the
firmware
and
then
upload
XCP
with
XSCF
Web
without
restarting
XSCF,
uploading
of
XCP
will
fail
and
the
XSCF
Web
session
will
time
out.
If
you
update
the
firmware
and
then
continue
to
upload
XCP
with
XSCF
Web,
restart
XSCF.
RTIF2-
121113-031
x
x
x
After
creating
an
I/O
domain
to
which
the
PCI
card
is
assigned
with
Oracle
VM
Server
for
SPARC,
turn
on
the
power
of
the
I/O
domain.
If
you
then
stop
it
in
ok
prompt,
the
configuration
information
of
the
PCI
card
may
not
be
displayed
with
the
showhardconf(8)
command
of
XSCF.
Start
Oracle
Solaris
of
the
logical
domain
to
which
the
PCI
card
is
assigned
with
Oracle
VM
Server
for
SPARC.
RTIF2-
121129-001
x
x
x
During
operation
of
the
XSCF
firmware,
a
"system
backup
memory
access
error",
which
is
an
error
in
the
PSU
backplane
(PSUBP),
may
be
erroneously
detected
and
registered
in
the
error
log.
If
this
erroneous
detection
occurs
during
the
start
process
of
the
physical
partition
(PPAR),
the
start
of
the
PPAR
may
fail.
Also,
if
it
occurs
during
the
collection
of
log
information,
the
log
information
collection
fails.
In
addition,
a
failure
mark
may
be
displayed
on
the
PSUBP
when
the
error
is
detected.
If
the
failure
mark
is
displayed
on
the
PSUBP,
the
resources
necessary
for
starting
the
PPAR
are
insufficient.
Therefore,
when
start
of
the
PPAR
is
requested,
a
log
indicating
that
the
start
of
the
PPAR
failed
is
registered
in
the
power
log.
You
can
display
the
power
log
with
the
showlogs
power
command.
If
you
find
a
log
described
in
"Description,"
execute
the
showstatus(8)
or
showhardconf
(8)
command
to
check
whether
the
failure
mark
is
displayed
on
the
PSUBP.
-
When
the
failure
mark
is
not
displayed
on
the
PSUBP:
No
problem
has
occurred
in
the
hardware.
So,
ignore
the
error
log
and
continue
the
operation.
-
When
the
failure
mark
is
displayed
on
the
PSUBP:
Clear
the
failure
mark
by
using
the
following
procedure.
1.
Switch
the
mode
switch
on
the
operation
panel
to
the
Service
mode
position.
2.
Turn
the
power
to
the
target
SPARC
M10
system
chassis
off
and
then
on
again,
and
then
restart
the
XSCF.
For
the
M10-4S,
turn
the
power
to
every
SPARC
M10-4S
chassis
off
and
then
on
again.
3.
After
the
XSCF
has
been
restarted,
return
the
mode
switch
on
the
operation
panel
to
its
original
position.
If
the
same
error
recurs
even
after
restarting
the
XSCF,
there
is
a
possibility
that
the
error
has
not
been
erroneously
detected
but
that
a
PSUBP
hardware
failure
has
occurred.
Ask
your
Fujitsu
field
engineer
(service
provider)
to
replace
the
PSUBP.
Chapter
3
Information
on
Software
147
Содержание M10 Series
Страница 8: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 viii ...
Страница 14: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 xiv ...
Страница 24: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 10 ...
Страница 192: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 178 ...
Страница 200: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 186 ...