Table
3-12
Problems
resolved
in
XCP
2210
(continued)
SPARC
M10-
RTI
No.
1
4
4S
Description
Workaround
RTIF2-
131213-004
x
x
x
If
the
PPAR
DR
feature
is
enabled/
disabled
on
XSCF
Web,
selecting
the
[PPAR
Operation]
-
[PPAR
Mode
Configuration]
menu
,
selecting
PPAR-DR(Current)
or
PPR-DR(Next)
and
clicking
[Configure],
a
wrong
dialogue
box
appears
and
the
PPAR
DR
feature
is
not
enabled
/
disabled.
Execute
the
XSCF
setpparmode(8)
command
to
enable/disable
the
PPAR
DR
feature.
RTIF2-
131213-008
x
In
a
configuration
with
3
or
more
BBs,
or
with
crossbar
boxes,
after
XSCF
switchover
occurs
due
to
some
problems
on
the
master
XSCF
while
the
"addboard
-c
configure"
command
is
running,
the
deleteboard(8)
command,
executed
on
the
new
master
XSCF
may
not
get
any
response.
This
symptom
occurs
if
two
master
XSCFs
exist
on
a
system
after
a
master/standby
switchover
of
XSCFs.
(Reference:
RTIF2-131213-001)
This
state
can
be
confirmed
by
a
lighted
MASTER
LED
at
the
rear
panel
of
two
chassis.
There
is
no
effective
workaround.
[How
to
restore]
Execute
the
deleteboard(8)
command
when
the
number
of
master
XSCFs
automatically
returns
to
one
after
a
few
minutes.
If
the
number
of
master
XSCFs
does
not
return
to
one
even
after
15
minutes,
press
the
RESET
switch
at
the
rear
panel
of
all
existing
SPARC
M10
system
and
crossbar
boxes.
Execute
the
deleteboard(8)
command
after
that.
RTIF2-
131213-009
x
The
"Failed
to
evacuate
board
resources"
message
may
be
output
when
the
addboard(8)
or
deleteboard(8)
command
of
the
DR
feature
is
executed
and
the
addition
or
removal
of
system
boards
with
DR
feature
fails.
Re-execute
the
addboard(8)
or
deleteboard(8)
command.
If
it
fails
again,
either
reboot
the
control
domain
or
reboot
the
XSCF
with
the
"rebootxscf
–a"
command.
After
that,
re-execute
the
addboard(8)
or
deleteboard(8)
command
of
the
DR
feature.
RTIF2-
131213-021
x
The
timeout
error
log
"Timeout
detected
during
unconfiguration
of
PSB#xx-x."
may
be
registered
and
an
abnormal
termination
may
occur
when
a
system
board
(PSB)
is
removed
by
the
deleteboard(8)
command
of
the
DR
feature.
In
such
a
case,
the
showboards(8)
command
shows
that
the
status
of
all
the
Pwr/Conn/Conf
of
the
system
board
(PSB)
is
"y".
There
is
no
effective
workaround.
[How
to
restore]
Reboot
all
the
XSCFs
by
executing
the
"rebootxscf
-a"
command.
Chapter
3
Information
on
Software
107
Содержание M10 Series
Страница 8: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 viii ...
Страница 14: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 xiv ...
Страница 24: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 10 ...
Страница 192: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 178 ...
Страница 200: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 186 ...