5.8: Correcting a Mismounted Unit
Issue 9, May 1999
FNC and FNC Customer Use Only
Vol. ll, Page 480.5-30
Maintenance and Trouble Clearing
FJTU-320-515-480
Step 8
Has the mismount cleared?
Step 9
Place the equipment slots back in service.
a. From the Provisioning menu, choose Service State, then choose Change
Equipment State.
b. Click the unit, then click on any nonselectable unit. A dialog box opens.
c. Select In Service.
d. Click OK.
Step 10
Place the facilities back in service.
a. From the Provisioning menu, choose Service State, then choose Change
Facility State.
b. Click the unit, then click on any nonselectable unit. A dialog box opens.
c. Select the appropriate Channel IDs.
d. Select In Service.
e. Click OK.
f. Click Retrieve to verify that the command was completed.
g. Click Close or Cancel.
Step 11
Were any cross-connects deleted in Step 4 that must be reconnected?
If Yes:
If No:
Call the Fujitsu Technical Assistance Center at
1-800-USE-FTAC (1-800-873-3822) for assistance.
If Yes:
If No:
You have completed this procedure.