3.13: BIP2ERR
Issue 9, May 1999
FNC and FNC Customer Use Only
Vol. ll, Page 480.3-13
Maintenance and Trouble Clearing
FJTU-320-515-480
3.13
BIP2ERR
3.14
CANVAL
3.15
CLEI-FLT
3.16
CLEI-LBC
Table 3-11: BIP2ERR (BIP2 Error Data Generated)—Standing Condition
AID
Type
Direction
Probable Cause
Suggested Corrective Action
VT1
TRMT
CONN-TSTSIG-VT1 has
been executed.
• Verify that the facility testing is complete.
• Execute the DISC-TSTSIG-VT1 command.
Table 3-12: CANVAL (CANC-VALTM Command Acceptable)—Transient Condition
AID
Type
Direction
Probable Cause
Suggested Corrective Action
COM
NA
NE can now accept cancel
validation timer for
software download (SWDL).
Send CANC-VALTM command to NE if new
software version is accepted by technician.
Table 3-13: CLEI-FLT (Plug-In Failure)—Alarm Event
AID
Type
Direction
Probable Cause
Suggested Corrective Action
EQPT
NA
The plug-in unit has failed.
Refer to Section 4, in this practice, or the Table of
Contents, located in the front of this practice, to
select the appropriate unit replacement
procedure.
Table 3-14: CLEI-LBC (Laser Bias Current Alarm)—Standing Condition
AID
Type
Direction
Probable Cause
Suggested Corrective Action
EQPT
NA
The laser diode mounted in
the LC1A card may be bad.
Refer to Section 4, in this practice, or the Table of
Contents, located in the front of this practice, to
select the appropriate unit replacement
procedure.