5.8: Correcting a Mismounted Unit
Issue 9, May 1999
FNC and FNC Customer Use Only
Vol. ll, Page 480.5-31
Maintenance and Trouble Clearing
FJTU-320-515-480
Step 12
Restore the cross-connects that were removed in Step 4.
a. From the Provisioning menu, choose Add/Drop.
b. Select Connect and the type of circuit to connect (1-Way, 2-Way, or
Broadcast).
c. Click on each end of the circuit to be connected and repeat for each circuit.
d. Click Send and check the resulting Confirmation box to verify that only
connections to the appropriate Group are slated for connection. If accurate,
click OK to make the connections.
e. Click on Close.
f. You have completed this procedure.
5.8.3
TL1 Procedure
Note: Verify that you receive a completed (COMPLD) response to each command before
going to the next step.
Step 1
Should the unit have been installed in another slot?
Step 2
Should another unit have been installed in the slot as the slot was provisioned?
If Yes:
If No:
Move the unit to the correct slot.
You have completed this procedure.
If Yes:
If No:
Replace the incorrect unit with a correct unit.
You have completed this procedure.