Chapter
8
Troubleshooting
132
When an error occurs, the Check LED lights in orange. For
temporary errors, the Function
N
umber Display on the Opera-
tor Panel indicates [J] or [U] and a number alternately; [E], [F],
[C], [H], [A], or [L] and a number alternately for device errors
(permanent errors). Temporary errors can be solved by the
operator, but the device errors (permanent errors) require
recovery works by support engineers. If you want to clear the
error indication, press the [Scan/Stop] or [Send to] button. The
scanner will return to the "Ready Status."
Once the Error Recovery Guide has been installed on your
computer, its window appears as soon as your Windows is
started up. When a temporary or device (permanent) error
occurs, this software displays information such as the error
name or error code regarding that error. Write down the infor-
mation displayed on the message box, and then click the
[More Info] button to learn detailed information for trouble-
shooting.
8
.2 Errors Indicated on the Operator Panel
Check
Function
Send to
Scan / Stop
Power
ADF type
[Send to] button
[Scan/Stop] button
Check LED
Function
N
umber Display
Check
Function
Send to
Power
Scan / Stop
Flatbed type
[Send to] button
[Scan/Stop] button
Function
N
umber Display
Check LED
The Error Recovery Guide is stored in the SETUP DVD-ROM.
For how to install this guide, refer to "Chapter 4 Installing the
Scanner Software" in the Getting Started.