6. SYSTEM DESIGN
Again, referring to the Settings List shown below, press the SELECT button (SW932), and
5)
display the code number of the function you want to set on the LED962.
Ex.) To select the Emergency Stop function
LED961
LED962
LED961
LED962
Next, press the ENTER button (SW933), and confirm the selection of the function you want to
set.
LED961
LED962
LED961
LED962
A flashing display on the LED962 changes to an illuminated display.
This completes FUNCTION SETTING.
To exit FUNCTION SETTING, press the ENTER button (SW933) in the setting completed
6)
status shown in step 5) above.
*2 : 5 seconds after, even if ENTER button(SW933) is not pressed , LED961 changes to a flashing display
automatically.
LED961
LED962
LED961
LED962
*2
Then, press the MODE/EXIT button (SW931) to exit FUNCTION SETTING MODE.
LED961
LED962
LED961
LED962
To set another function, press the ENTER button (SW933) in the setting completed status
7)
shown in step 5) above.
LED961
LED962
LED961
LED962
Repeat steps 4) and 5) above to set other functions.
When all settings are complete, perform the operation described in step 6) above to exit.
RESET THE POWER AFTER SETTING UP FUNCTION OF
OUTDOOR UNIT
Important
If the reset is not performed, function can not be read in normally.
After all the functions have been set, the circuit breaker needs to be switched off
for at least 2 minutes.
After the 2 minutes has passed, power can be restored.
The set function is stored in the PCB and will remain in memory even when the
power is turned off.
However setting function is effective after power reset.
Record the function set in the outdoor unit on a label, etc., and affix the label to the
unit so it can be used for after-sales service operations.
- (06 - 52) -
SY
S
T
E
M
DE
SIGN
SY
S
T
E
M
DE
SIGN
Содержание ARU12RLF
Страница 1: ...VD014E 06 FUJITSU GENERAL LIMITED DESIGN TECHNICAL MANUAL Hybrid Flex Inverter System DTR_BMU001E_05 ...
Страница 3: ...1 GENERAL INFORMATION DTR_BMU001E_03 CHAPTER01 2010 08 25 Hybrid Flex Inverter System ...
Страница 18: ...2 MODEL SELECTION DTR_BMU001E_04 CHAPTER02 2010 10 04 Hybrid Flex Inverter System ...
Страница 38: ...3 OUTDOOR UNIT BRANCH BOX Hybrid Flex Inverter System DTR_BMU001E_04 CHAPTER03 2010 10 04 ...
Страница 58: ...4 INDOOR UNITS Hybrid Flex Inverter System DTR_BMU001E_05 CHAPTER04 2010 11 12 ...
Страница 82: ...4 INDOOR UNITS SLIM DUCT TYPE 5 2 MODELS ARU9RLF ARU12RLF ARU18RLF ARU24RLF 04 22 INDOOR UNITS INDOOR UNITS ...
Страница 83: ...4 INDOOR UNITS COMPACT WALL MOUNTED TYPE 5 3 MODELS AS U7RLF ASU9RLF ASU12RLF 04 23 INDOOR UNITS INDOOR UNITS ...
Страница 84: ...4 INDOOR UNITS WALL MOUNTED TYPE 5 4 MODELS AS U18RLF ASU24RLF 04 24 INDOOR UNITS INDOOR UNITS ...
Страница 116: ...5 CONTROL SYSTEM DTR_BMU001E_04 CHAPTER05 2010 10 04 Hybrid Flex Inverter System ...
Страница 152: ...6 SYSTEM DESIGN DTR_BMU001E_04 CHAPTER06 2010 10 04 Hybrid Flex Inverter System ...
Страница 287: ...7 OPTIONAL PARTS Hybrid Flex Inverter System DTR_BMU001E_03 CHAPTER07 2010 08 25 ...
Страница 288: ...CONTENTS 7 OPTIONAL PARTS 1 SEPARATION TUBE 07 01 2 BRANCH BOX 07 02 3 CONTROLLER 07 04 4 OTHERS 07 05 ...